CVE-2011-3386
Summary
| CVE | CVE-2011-3386 |
|---|---|
| State | PUBLISHED |
| Assigner | mitre |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2011-09-02 23:55:05 UTC |
| Updated | 2026-04-29 01:13:23 UTC |
| Description | Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service (adverse human health effects) via unspecified vectors involving wireless communications and knowledge of the device's serial number, as demonstrated by Jerome Radcliffe at the Black Hat USA conference in August 2011. NOTE: the vendor has disputed the severity of this issue, saying "we believe the risk of deliberate, malicious, or unauthorized manipulation of medical devices is extremely low... we strongly believe it would be extremely difficult for a third-party to wirelessly tamper with your insulin pump... you would be able to detect tones on the insulin pump that weren't intentionally programmed and could intervene accordingly." |
Risk And Classification
Primary CVSS: v2.0 4 from [email protected]
AV:N/AC:H/Au:N/C:N/I:P/A:P
Problem Types: NVD-CWE-noinfo | n/a
CVSS v2.0 Breakdown
Access Vector
NetworkAccess Complexity
HighAuthentication
NoneConfidentiality
NoneIntegrity
PartialAvailability
PartialAV:N/AC:H/Au:N/C:N/I:P/A:P
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Medtronic | Paradigm Wireless Insulin Pump | 512 | All | All | All |
| Hardware | Medtronic | Paradigm Wireless Insulin Pump | 522 | All | All | All |
| Hardware | Medtronic | Paradigm Wireless Insulin Pump | 712 | All | All | All |
| Hardware | Medtronic | Paradigm Wireless Insulin Pump | 722 | All | All | All |
Vendor Declared Affected Products
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| IBM X-Force Exchange | af854a3a-2127-422b-91ae-364da2661108 | exchange.xforce.ibmcloud.com | |
| Insulin Pump Hack Controversy Grows - Security - Vulnerabilities and threats - Informationweek | af854a3a-2127-422b-91ae-364da2661108 | www.informationweek.com | |
| Hackers can kill Diabetics with Insulin Pumps from a half mile away - Um, no. Facts vs. Journalistic Fear mongering - Scott Hanselman | af854a3a-2127-422b-91ae-364da2661108 | www.hanselman.com | |
| Insulin Pumps Vulnerable To Hacking | Fox News | af854a3a-2127-422b-91ae-364da2661108 | www.foxnews.com | |
| Six Until Me.: Hacked: Jay Radcliffe, Insulin Pumps, and Diabetes Sensationalism. | af854a3a-2127-422b-91ae-364da2661108 | sixuntilme.com | |
| www.loop-blog.com/Blog_Full_Post | af854a3a-2127-422b-91ae-364da2661108 | www.loop-blog.com | |
| www.darkreading.com/security/vulnerabilities/231300312/getting-root-on-the-human-... | af854a3a-2127-422b-91ae-364da2661108 | www.darkreading.com | |
| Black Hat: Insulin pumps can be hacked - SC Magazine US | af854a3a-2127-422b-91ae-364da2661108 | www.scmagazineus.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.