Nordex NC2 Cross-site Scripting

Summary

CVECVE-2014-5408
StatePUBLISHED
Assignericscert
Source PriorityCVE Program / NVD first with legacy fallback
Published2014-11-05 11:55:06 UTC
Updated2026-05-06 22:30:45 UTC
DescriptionCross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter.

Risk And Classification

Primary CVSS: v2.0 4.3 from [email protected]

AV:N/AC:M/Au:N/C:N/I:P/A:N

Problem Types: CWE-79 | CWE-79 CWE-79


VersionSourceTypeScoreSeverityVector
2.0[email protected]Primary4.3AV:N/AC:M/Au:N/C:N/I:P/A:N
2.0[email protected]Secondary7.5AV:N/AC:L/Au:N/C:P/I:P/A:P
2.0CNACVSS7.5AV:N/AC:L/Au:N/C:P/I:P/A:P

CVSS v2.0 Breakdown

Access Vector
Network
Access Complexity
Medium
Authentication
None
Confidentiality
None
Integrity
Partial
Availability
None

AV:N/AC:M/Au:N/C:N/I:P/A:N

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Hardware Nordex Nordex Control 2 Scada All All All All

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Nordex Nordex Control 2 NC2 SCADA affected 15 custom Not specified

References

ReferenceSourceLinkTags
Malformed Request af854a3a-2127-422b-91ae-364da2661108 www.securityfocus.com
github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-30... [email protected] github.com
Nordex NC2 XSS Vulnerability | ICS-CERT af854a3a-2127-422b-91ae-364da2661108 ics-cert.us-cert.gov Third Party Advisory, US Government Resource
www.cisa.gov/news-events/ics-advisories/icsa-14-303-01 [email protected] www.cisa.gov
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Darius Freamon (en)

Additional Advisory Data

Solutions

CNA: Nordex will release a patch for all affected NC2-SCADA versions until the end of 2014. The patching of the NC2-SCADA system has to be done by Nordex. Nordex will upgrade all wind farms with a valid service contract to the patched version of the NC2-SCADA in coordination with normal maintenance operations. Owners of Nordex NC2-based wind farms without a valid service contract can order the patch from Nordex by contacting their local Nordex service organization.

© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.