Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function
Summary
| CVE | CVE-2014-9197 |
|---|---|
| State | PUBLISHED |
| Assigner | icscert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2015-01-27 19:59:00 UTC |
| Updated | 2026-05-06 22:30:45 UTC |
| Description | The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request. |
Risk And Classification
Primary CVSS: v2.0 7.8 from [email protected]
AV:N/AC:L/Au:N/C:C/I:N/A:N
Problem Types: CWE-306 | CWE-284 | CWE-306 CWE-306
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 2.0 | [email protected] | Primary | 7.8 | AV:N/AC:L/Au:N/C:C/I:N/A:N | |
| 2.0 | [email protected] | Secondary | 10 | AV:N/AC:L/Au:N/C:C/I:C/A:C | |
| 2.0 | CNA | CVSS | 10 | AV:N/AC:L/Au:N/C:C/I:C/A:C |
CVSS v2.0 Breakdown
AV:N/AC:L/Au:N/C:C/I:N/A:N
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Operating System | Schneider-electric | Etg3000 Factorycast Hmi Gateway Firmware | 1.60.2 | All | All | All |
| Hardware | Schneider-electric | Tsxetg3000 | - | All | All | All |
| Hardware | Schneider-electric | Tsxetg3010 | - | All | All | All |
| Hardware | Schneider-electric | Tsxetg3021 | - | All | All | All |
| Hardware | Schneider-electric | Tsxetg3022 | - | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Schneider Electric | ETG3000 FactoryCast HMI Gateway | affected TSXETG3000 | Not specified |
| CNA | Schneider Electric | ETG3000 FactoryCast HMI Gateway | affected TSXETG3010 | Not specified |
| CNA | Schneider Electric | ETG3000 FactoryCast HMI Gateway | affected TSXETG3021 | Not specified |
| CNA | Schneider Electric | ETG3000 FactoryCast HMI Gateway | affected TSXETG3022 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Schneider Electric ETG3000 FactoryCast HMI Gateway Vulnerabilities | ICS-CERT | af854a3a-2127-422b-91ae-364da2661108 | ics-cert.us-cert.gov | Patch, US Government Resource |
| www.cisa.gov/news-events/ics-advisories/icsa-15-020-02 | [email protected] | www.cisa.gov | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Narendra Shinde of Qualys Security (en)
Additional Advisory Data
Solutions
CNA: Schneider Electric has produced an updated firmware, labelled V1.60 IR 04. This firmware release moves the jar files directory in a secure area. The new firmware also includes the ability to disable the FTP server. This updated firmware can be downloaded at: http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe... http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/
Workarounds
CNA: Schneider Electric recommends the FTP server be deactivated when not needed. The firmware update does not remove the hard-coded credentials. Narendra Shinde also found that configuration files were accessible using default credentials. Schneider Electric recommends users change the default login credentials. This will protect configuration files from unauthorized access.
Legacy QID Mappings
- 590491 Schneider Electric ETG3000 FactoryCast HMI Gateway Multiple Vulnerabilities (ICSA-15-020-02)