CVE-2015-1142857
Summary
| CVE | CVE-2015-1142857 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2018-01-23 14:29:00 UTC |
| Updated | 2018-02-15 17:23:00 UTC |
| Description | On multiple SR-IOV cars it is possible for VF's assigned to guests to send ethernet flow control pause frames via the PF. This includes Linux kernel ixgbe driver before commit f079fa005aae08ee0e1bc32699874ff4f02e11c1, the Linux Kernel i40e/i40evf driver before e7358f54a3954df16d4f87e3cad35063f1c17de5 and the DPDK before commit 3f12b9f23b6499ff66ec8b0de941fb469297e5d0, additionally Multiple vendor NIC firmware is affected. |
Risk And Classification
Problem Types: CWE-254
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Operating System | Dpdk | Dpdk | - | All | All | All |
| Operating System | Dpdk | Dpdk | - | All | All | All |
| Hardware | Intel | 82576 | - | All | All | All |
| Hardware | Intel | 82576 | - | All | All | All |
| Operating System | Intel | 82576 Firmware | - | All | All | All |
| Operating System | Intel | 82576 Firmware | - | All | All | All |
| Hardware | Intel | 82599 | - | All | All | All |
| Hardware | Intel | 82599 | - | All | All | All |
| Operating System | Intel | 82599 Firmware | - | All | All | All |
| Operating System | Intel | 82599 Firmware | - | All | All | All |
| Hardware | Intel | I350 | - | All | All | All |
| Hardware | Intel | I350 | - | All | All | All |
| Operating System | Intel | I350 Firmware | - | All | All | All |
| Operating System | Intel | I350 Firmware | - | All | All | All |
| Hardware | Intel | X540 | - | All | All | All |
| Hardware | Intel | X540 | - | All | All | All |
| Operating System | Intel | X540 Firmware | - | All | All | All |
| Operating System | Intel | X540 Firmware | - | All | All | All |
| Hardware | Intel | X710 | - | All | All | All |
| Hardware | Intel | X710 | - | All | All | All |
| Operating System | Intel | X710 Firmware | - | All | All | All |
| Operating System | Intel | X710 Firmware | - | All | All | All |
| Operating System | Linux | Linux Kernel I40e/i40evf | - | All | All | All |
| Operating System | Linux | Linux Kernel I40e/i40evf | - | All | All | All |
| Operating System | Linux | Linux Kernel I40e/i40evf | - | All | All | All |
| Operating System | Linux | Linux Kernel Ixgbe | - | All | All | All |
| Operating System | Linux | Linux Kernel Ixgbe | - | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Intel® Product Security Center | CONFIRM | security-center.intel.com | Mitigation, Vendor Advisory |
| oss-sec: CVE request -- Ethernet flow control vulnerability in SRIOV devices | MLIST | seclists.org | Mailing List, Patch, Third Party Advisory |
| www.usenix.org/system/files/conference/usenixsecurity15/sec15-paper-smolyar.pdf | MISC | www.usenix.org | Technical Description, Third Party Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.