CVE-2015-7937

Summary

CVECVE-2015-7937
StatePUBLIC
Assigner[email protected]
Source PriorityCVE Program / NVD first with legacy fallback
Published2015-12-21 11:59:00 UTC
Updated2016-11-28 19:45:00 UTC
DescriptionStack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.

Risk And Classification

Problem Types: CWE-119

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Hardware Schneider-electric Bmxnoc0401 - All All All
Hardware Schneider-electric Bmxnoc0401 - All All All
Hardware Schneider-electric Bmxnoe0100 - All All All
Hardware Schneider-electric Bmxnoe0100 - All All All
Hardware Schneider-electric Bmxnoe0100h - All All All
Hardware Schneider-electric Bmxnoe0100h - All All All
Hardware Schneider-electric Bmxnoe0110 - All All All
Hardware Schneider-electric Bmxnoe0110 - All All All
Hardware Schneider-electric Bmxnoe0110h - All All All
Hardware Schneider-electric Bmxnoe0110h - All All All
Hardware Schneider-electric Bmxnor0200 - All All All
Hardware Schneider-electric Bmxnor0200 - All All All
Hardware Schneider-electric Bmxnor0200h - All All All
Hardware Schneider-electric Bmxnor0200h - All All All
Hardware Schneider-electric Bmxp342020 - All All All
Hardware Schneider-electric Bmxp342020 - All All All
Hardware Schneider-electric Bmxp342020h - All All All
Hardware Schneider-electric Bmxp342020h - All All All
Hardware Schneider-electric Bmxp342030 - All All All
Hardware Schneider-electric Bmxp342030 - All All All
Hardware Schneider-electric Bmxp3420302 - All All All
Hardware Schneider-electric Bmxp3420302 - All All All
Hardware Schneider-electric Bmxp3420302h - All All All
Hardware Schneider-electric Bmxp3420302h - All All All
Hardware Schneider-electric Bmxpra0100 - All All All
Hardware Schneider-electric Bmxpra0100 - All All All

References

ReferenceSourceLinkTags
Schneider Electric Modicon M340 Buffer Overflow Vulnerability | ICS-CERT MISC ics-cert.us-cert.gov Third Party Advisory, US Government Resource
download.schneider-electric.com/files CONFIRM download.schneider-electric.com Vendor Advisory
Schneider Electric Modicon M340 CVE-2015-7937 Stack Buffer Overflow Vulnerability BID www.securityfocus.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Legacy QID Mappings

  • 590492 Schneider Electric Modicon M340 Buffer Overflow Vulnerability Vulnerability (ICSA-15-351-01)
© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.