CVE-2016-2201
Published on: 02/08/2016 12:00:00 AM UTC
Last Modified on: 03/23/2021 11:27:15 PM UTC
Certain versions of Simatic S7-1500 Cpu Firmware from Siemens contain the following vulnerability:
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102.
- CVE-2016-2201 has been assigned by
[email protected] to track the vulnerability - currently rated as MEDIUM severity.
CVSS3 Score: 5.3 - MEDIUM
Attack Vector ⓘ |
Attack Complexity |
Privileges Required |
User Interaction |
|
---|---|---|---|---|
NETWORK | LOW | NONE | NONE | |
Scope | Confidentiality Impact |
Integrity Impact |
Availability Impact |
|
UNCHANGED | NONE | LOW | NONE |
CVSS2 Score: 5 - MEDIUM
Access Vector ⓘ |
Access Complexity |
Authentication |
---|---|---|
NETWORK | LOW | NONE |
Confidentiality Impact |
Integrity Impact |
Availability Impact |
NONE | PARTIAL | NONE |
CVE References
Description | Tags ⓘ | Link |
---|---|---|
Siemens | Vendor Advisory www.siemens.com text/html |
![]() |
Siemens SIMATIC S7-1500 CPU Controller Bugs Let Remote Users Bypass Replay Security Mechanisms and Deny Service - SecurityTracker | Third Party Advisory VDB Entry www.securitytracker.com text/html |
![]() |
Siemens SIMATIC S7-1500 CPU Vulnerabilities | ICS-CERT | Third Party Advisory US Government Resource ics-cert.us-cert.gov text/html |
![]() |
cert-portal.siemens.com application/pdf |
![]() | |
Siemens SIMATIC S7-1500 CVE-2016-2201 Security Bypass Vulnerability | Third Party Advisory VDB Entry cve.report (archive) text/html |
![]() |
Known Affected Configurations (CPE V2.3)
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:1.8.2:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:1.8.2:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1511-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1511-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1511c-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1511c-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1511f-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1511f-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1512c-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1512c-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1513-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1513-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1513f-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1513f-1_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1515-2_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1515-2_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1515f-2_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1515f-2_pn_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1516-3_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1516-3_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1516f-3_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1516f-3_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1517-3_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1517-3_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1517f-3_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1517f-3_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1518-4_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1518-4_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1518f-4_pn\/dp_cpu:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1518f-4_pn\/dp_cpu:-:*:*:*:*:*:*:*:
No vendor comments have been submitted for this CVE