CVE-2016-8354
Summary
| CVE | CVE-2016-8354 |
|---|---|
| State | PUBLISHED |
| Assigner | icscert |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2017-02-13 21:59:00 UTC |
| Updated | 2025-04-20 01:37:25 UTC |
| Description | An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions. |
Risk And Classification
Primary CVSS: v3.0 7 HIGH from [email protected]
CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
Problem Types: CWE-94 | Schneider Electric Unity PRO Control Flow Management Vulnerability
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.0 | [email protected] | Primary | 7 | HIGH | CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H |
| 2.0 | [email protected] | Primary | 5.1 | AV:N/AC:H/Au:N/C:P/I:P/A:P |
CVSS v3.0 Breakdown
Attack Vector
LocalAttack Complexity
HighPrivileges Required
NoneUser Interaction
RequiredScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS v2.0 Breakdown
Access Vector
NetworkAccess Complexity
HighAuthentication
NoneConfidentiality
PartialIntegrity
PartialAvailability
PartialAV:N/AC:H/Au:N/C:P/I:P/A:P
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Schneider-electric | Unity Pro | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Na | Schneider Electric Unity PRO Control Prior To V11.1 | affected Schneider Electric Unity PRO Control prior to V11.1 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Schneider Electric Unity PRO Control Flow Management Vulnerability | ICS-CERT | af854a3a-2127-422b-91ae-364da2661108 | ics-cert.us-cert.gov | Third Party Advisory, US Government Resource |
| Schneider Electric Unity PRO Insecure File Downloading Remote Code Execution Vulnerability | af854a3a-2127-422b-91ae-364da2661108 | www.securityfocus.com | Third Party Advisory, VDB Entry |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.