CVE-2017-10723

Summary

CVECVE-2017-10723
StatePUBLIC
Assigner[email protected]
Source PriorityCVE Program / NVD first with legacy fallback
Published2019-06-17 22:15:00 UTC
Updated2019-06-20 19:10:00 UTC
DescriptionRecently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures viewed by that user and might allow them to get a foot hold in air gapped networks especially in case of nation critical infrastructure/industries. The firmware contains binary uvc_stream that is the UDP daemon which is responsible for handling all the UDP requests that the device receives. The client application sends a UDP request to change the Wi-Fi name which contains the following format: "SETCMD0001+0001+[2 byte length of wifiname]+[Wifiname]. This request is handled by "control_Dev_thread" function which at address "0x00409AE0" compares the incoming request and determines if the 10th byte is 01 and if it is then it redirects to 0x0040A74C which calls the function "setwifiname". The function "setwifiname" uses a memcpy function but uses the length of the payload obtained by using strlen function as the third parameter which is the number of bytes to copy and this allows an attacker to overflow the function and control the $PC value.

Risk And Classification

Problem Types: CWE-119

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Hardware Ishekar Endoscope Camera - All All All
Hardware Ishekar Endoscope Camera - All All All
Operating System Ishekar Endoscope Camera Firmware All All All All
Operating System Ishekar Endoscope Camera Firmware All All All All

References

ReferenceSourceLinkTags
IoT_vulnerabilities/Shekar_boriscope_sec_issues.pdf at master · ethanhunnt/IoT_vulnerabilities · GitHub MISC github.com Exploit, Third Party Advisory
Shekar Endoscope Weak Default Settings / Memory Corruption ≈ Packet Storm MISC packetstormsecurity.com Third Party Advisory, VDB Entry
Bugtraq: Newly releases IoT security issues BUGTRAQ seclists.org Mailing List, Third Party Advisory
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report