CVE-2017-2680
Published on: 05/10/2017 12:00:00 AM UTC
Last Modified on: 04/12/2022 06:29:00 PM UTC
Certain versions of Dk Standard Ethernet Controller from Siemens contain the following vulnerability:
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
- CVE-2017-2680 has been assigned by
productc[email protected] to track the vulnerability - currently rated as MEDIUM severity.
CVSS3 Score: 6.5 - MEDIUM
Attack Vector ⓘ |
Attack Complexity |
Privileges Required |
User Interaction |
---|---|---|---|
ADJACENT_NETWORK | LOW | NONE | NONE |
Scope | Confidentiality Impact |
Integrity Impact |
Availability Impact |
UNCHANGED | NONE | NONE | HIGH |
CVSS2 Score: 6.1 - MEDIUM
Access Vector ⓘ |
Access Complexity |
Authentication |
---|---|---|
ADJACENT_NETWORK | LOW | NONE |
Confidentiality Impact |
Integrity Impact |
Availability Impact |
NONE | NONE | COMPLETE |
CVE References
Description | Tags ⓘ | Link |
---|---|---|
Vendor Advisory cert-portal.siemens.com application/pdf |
![]() | |
Siemens SIMATIC Controller PROFINET DCP Packet Processing Bugs Let Remote Users Deny Service - SecurityTracker | Third Party Advisory VDB Entry www.securitytracker.com text/html |
![]() |
Vendor Advisory cert-portal.siemens.com application/pdf |
![]() | |
No Description Provided | Third Party Advisory VDB Entry cve.report (archive) text/html |
![]() |
Siemens | Broken Link www.siemens.com text/html |
![]() |
Siemens Industrial Products (Update A) | CISA | Third Party Advisory US Government Resource ics-cert.us-cert.gov text/html |
![]() |
Vendor Advisory cert-portal.siemens.com application/pdf |
![]() |
There are currently no QIDs associated with this CVE
Known Affected Configurations (CPE V2.3)
- cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ie/as-i_link_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ie/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ie/pb-link:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ie/pb-link_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ie\/as-i_link_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ie\/as-i_link_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ie\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ie\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ie\/pb-link:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ie\/pb-link:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ie\/pb-link_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ie\/pb-link_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:pn/pn_coupler:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:pn/pn_coupler_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:pn\/pn_coupler:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:pn\/pn_coupler:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:pn\/pn_coupler_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:pn\/pn_coupler_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-7_lte/us:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-7_lte/us_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-7_lte\/us:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-7_lte\/us:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-7_lte\/us_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-7_lte\/us_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g120(c/p/d)_w._pn:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g120(c/p/d)_w._pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g120(c/p/d)_w._pn_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g120\(c\/p\/d\)_w._pn:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g120\(c\/p\/d\)_w._pn:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g120\(c\/p\/d\)_w._pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g120\(c\/p\/d\)_w._pn_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g120\(c\/p\/d\)_w._pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g120\(c\/p\/d\)_w._pn_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:*:
No vendor comments have been submitted for this CVE