| Description | In EMC VNX2 versions prior to OE for File 8.1.9.211 and VNX1 versions prior to OE for File 7.1.80.8, a local authenticated user may potentially escalate their privileges to root due to authorization checks not being performed on certain perl scripts. This may potentially be exploited by an attacker to run arbitrary commands as root on the targeted VNX Control Station system. |
Risk And Classification
Primary CVSS: v3.0 7.8 HIGH from [email protected]
CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Problem Types: CWE-862 | Local privilege escalation vulnerability
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.0 | [email protected] | Primary | 7.8 | HIGH | CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| 2.0 | [email protected] | Primary | 7.2 | AV:L/AC:L/Au:N/C:C/I:C/A:C |
CVSS v3.0 Breakdown
Attack Vector
LocalAttack Complexity
LowPrivileges Required
LowUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS v2.0 Breakdown
Access Vector
LocalAccess Complexity
LowAuthentication
NoneConfidentiality
CompleteIntegrity
CompleteAvailability
CompleteAV:L/AC:L/Au:N/C:C/I:C/A:C
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Emc | Vnx1 | - | All | All | All |
| Operating System | Emc | Vnx1 Firmware | - | All | All | All |
| Hardware | Emc | Vnx2 | - | All | All | All |
| Operating System | Emc | Vnx2 Firmware | - | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Na | EMC VNX2 Versions Prior To OE For File 8.1.9.211 EMC VNX1 Versions Prior To OE For File 7.1.80.8 | affected EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| EMC VNX1/VNX2 OE for File CVE-2017-4985 Local Privilege Escalation Vulnerability | af854a3a-2127-422b-91ae-364da2661108 | www.securityfocus.com | Third Party Advisory, VDB Entry |
| SecurityFocus | af854a3a-2127-422b-91ae-364da2661108 | www.securityfocus.com | Third Party Advisory, VDB Entry |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.