Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

Summary

CVECVE-2017-6034
StatePUBLISHED
Assignericscert
Source PriorityCVE Program / NVD first with legacy fallback
Published2017-06-30 03:29:00 UTC
Updated2026-06-04 22:16:51 UTC
DescriptionAn authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.

Risk And Classification

Primary CVSS: v3.1 9.8 CRITICAL from ADP

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

EPSS: 0.001440000 probability, percentile 0.344240000 (date 2026-06-09)

Problem Types: CWE-294 | CWE-287 | CWE-294 CWE-294


VersionSourceTypeScoreSeverityVector
3.1ADPDECLARED9.8CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.1134c704f-9b21-4f2e-91b3-4a467353bcc0Secondary9.8CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.0[email protected]Primary9.8CRITICALCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
2.0[email protected]Primary7.5AV:N/AC:L/Au:N/C:P/I:P/A:P

CVSS v3.1 Breakdown

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS v3.0 Breakdown

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS v2.0 Breakdown

Access Vector
Network
Access Complexity
Low
Authentication
None
Confidentiality
Partial
Integrity
Partial
Availability
Partial

AV:N/AC:L/Au:N/C:P/I:P/A:P

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Hardware Schneider-electric Modbus - All All All
Operating System Schneider-electric Modbus Firmware - All All All

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Schneider Electric Modicon Modbus Protocol affected all versions Not specified

References

ReferenceSourceLinkTags
Schneider Electric Modicon Modbus Protocol Multiple Authentication Bypass Vulnerabilities af854a3a-2127-422b-91ae-364da2661108 www.securityfocus.com Third Party Advisory, VDB Entry
www.se.com/us/en/download/document/SEVD-2017-065-01 [email protected] www.se.com
github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-10... [email protected] github.com
Schneider Electric Modicon Modbus Protocol | ICS-CERT af854a3a-2127-422b-91ae-364da2661108 ics-cert.us-cert.gov Third Party Advisory, US Government Resource
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Eran Goldstein of CRITIFENCE reported the identified vulnerabilities. (en)

Additional Advisory Data

Workarounds

CNA: Schneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency. Schneider Electric’s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures: * Protect access to M1E controllers by a firewall blocking all remote/external access to Port 502. Schneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures: * Enable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program; * Enable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and * Enable the “Access Control List protection,” where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC. For additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location: https://www.se.com/us/en/download/document/SEVD-2017-065-01/

Legacy QID Mappings

  • 590766 Schneider Electric Modicon Controllers and SCADAPack RTU Vulnerability (SEVD-2017-065-01)
© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.