CVE-2017-8226

Summary

CVECVE-2017-8226
StatePUBLIC
Assigner[email protected]
Source PriorityCVE Program / NVD first with legacy fallback
Published2019-07-03 20:15:00 UTC
Updated2019-07-11 01:49:00 UTC
DescriptionAmcrest IPM-721S V2.420.AC00.16.R.20160909 devices have default credentials that are hardcoded in the firmware and can be extracted by anyone who reverses the firmware to identify them. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable function that sets up the default credentials on the device. If one opens this binary in IDA-pro, one will notice that this follows a ARM little endian format. The function sub_3DB2FC in IDA pro is identified to be setting up the values at address 0x003DB5A6. The sub_5C057C then sets this value and adds it to the Configuration files in /mnt/mtd/Config/Account1 file.

Risk And Classification

Problem Types: CWE-798

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Hardware Amcrest Ipm-721s - All All All
Hardware Amcrest Ipm-721s - All All All
Operating System Amcrest Ipm-721s Firmware All All All All

References

ReferenceSourceLinkTags
Amcrest IPM-721S Credential Disclosure / Privilege Escalation ≈ Packet Storm MISC packetstormsecurity.com Third Party Advisory, VDB Entry
Bugtraq: Newly releases IoT security issues BUGTRAQ seclists.org Mailing List, Third Party Advisory
IoT_vulnerabilities/Amcrest_sec_issues.pdf at master · ethanhunnt/IoT_vulnerabilities · GitHub MISC github.com Exploit, Third Party Advisory
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis
© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

CVE.report and Source URL Uptime Status status.cve.report