CVE-2018-11421
Summary
| CVE | CVE-2018-11421 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2019-07-03 16:15:00 UTC |
| Updated | 2020-08-24 17:37:00 UTC |
| Description | Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages. |
Risk And Classification
Problem Types: CWE-319
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Moxa | Oncell G3150-hspa | - | All | All | All |
| Hardware | Moxa | Oncell G3150-hspa | - | All | All | All |
| Hardware | Moxa | Oncell G3150-hspa-t | - | All | All | All |
| Hardware | Moxa | Oncell G3150-hspa-t | - | All | All | All |
| Operating System | Moxa | Oncell G3150-hspa-t Firmware | All | All | All | All |
| Operating System | Moxa | Oncell G3150-hspa Firmware | All | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Advisories/KL-MOXA-2018-103.md at master · klsecservices/Advisories · GitHub | MISC | github.com | Third Party Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.