CVE-2018-11461
Summary
| CVE | CVE-2018-11461 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2018-12-12 16:29:00 UTC |
| Updated | 2019-10-09 23:33:00 UTC |
| Description | A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
Risk And Classification
Problem Types: NVD-CWE-noinfo
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Siemens | Sinumerik 808d V4.7 | - | All | All | All |
| Hardware | Siemens | Sinumerik 808d V4.7 | - | All | All | All |
| Operating System | Siemens | Sinumerik 808d V4.7 Firmware | All | All | All | All |
| Operating System | Siemens | Sinumerik 808d V4.7 Firmware | All | All | All | All |
| Hardware | Siemens | Sinumerik 808d V4.8 | - | All | All | All |
| Hardware | Siemens | Sinumerik 808d V4.8 | - | All | All | All |
| Operating System | Siemens | Sinumerik 808d V4.8 Firmware | All | All | All | All |
| Operating System | Siemens | Sinumerik 808d V4.8 Firmware | All | All | All | All |
| Hardware | Siemens | Sinumerik 828d V4.7 | - | All | All | All |
| Hardware | Siemens | Sinumerik 828d V4.7 | - | All | All | All |
| Operating System | Siemens | Sinumerik 828d V4.7 Firmware | All | All | All | All |
| Hardware | Siemens | Sinumerik 840d Sl V4.7 | All | All | All | All |
| Hardware | Siemens | Sinumerik 840d Sl V4.7 | All | All | All | All |
| Operating System | Siemens | Sinumerik 840d Sl V4.7 Firmware | All | All | All | All |
| Hardware | Siemens | Sinumerik 840d Sl V4.8 | - | All | All | All |
| Hardware | Siemens | Sinumerik 840d Sl V4.8 | - | All | All | All |
| Operating System | Siemens | Sinumerik 840d Sl V4.8 Firmware | All | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf | CONFIRM | cert-portal.siemens.com | Vendor Advisory |
| Siemens SINUMERIK Controllers Multiple Security Vulnerabilities | BID | www.securityfocus.com | Third Party Advisory, VDB Entry |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.