CVE-2018-13807
Summary
| CVE | CVE-2018-13807 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2018-09-12 13:29:00 UTC |
| Updated | 2019-10-09 23:34:00 UTC |
| Description | A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools. |
Risk And Classification
Problem Types: CWE-20
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Siemens | Scalance X300 | - | All | All | All |
| Hardware | Siemens | Scalance X300 | - | All | All | All |
| Operating System | Siemens | Scalance X300 Firmware | All | All | All | All |
| Operating System | Siemens | Scalance X300 Firmware | All | All | All | All |
| Hardware | Siemens | Scalance X408 | - | All | All | All |
| Hardware | Siemens | Scalance X408 | - | All | All | All |
| Operating System | Siemens | Scalance X408 Firmware | All | All | All | All |
| Operating System | Siemens | Scalance X408 Firmware | All | All | All | All |
| Hardware | Siemens | Scalance X414 | - | All | All | All |
| Hardware | Siemens | Scalance X414 | - | All | All | All |
| Operating System | Siemens | Scalance X414 Firmware | - | All | All | All |
| Operating System | Siemens | Scalance X414 Firmware | - | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Malformed Request | BID | www.securityfocus.com | Third Party Advisory, VDB Entry |
| Siemens SCALANCE X Switches | ICS-CERT | MISC | ics-cert.us-cert.gov | Third Party Advisory, US Government Resource, VDB Entry |
| cert-portal.siemens.com/productcert/pdf/ssa-447396.pdf | CONFIRM | cert-portal.siemens.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.