CVE-2018-16669
Summary
| CVE | CVE-2018-16669 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2018-09-18 20:29:00 UTC |
| Updated | 2019-10-03 00:03:00 UTC |
| Description | An issue was discovered in CIRCONTROL Open Charge Point Protocol (OCPP) before 1.5.0, as used in CirCarLife, PowerStudio, and other products. Due to storage of credentials in XML files, an unprivileged user can look at /services/config/config.xml for the admin credentials of the ocpp and circarlife panels. |
Risk And Classification
Problem Types: CWE-522
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Circontrol | Open Charge Point Protocol | All | All | All | All |
| Application | Circontrol | Open Charge Point Protocol | All | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| CirCarLife SCADA 4.3.0 - Credential Disclosure - Hardware webapps Exploit | EXPLOIT-DB | www.exploit-db.com | Exploit, Third Party Advisory, VDB Entry |
| Exploits/Real World/Suites/cir-pwn-life at master · SadFud/Exploits · GitHub | MISC | github.com | Exploit |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.