CVE-2018-18706
Summary
| CVE | CVE-2018-18706 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2018-10-29 12:29:00 UTC |
| Updated | 2018-12-14 16:27:00 UTC |
| Description | An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. |
Risk And Classification
Problem Types: CWE-119
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Tenda | Ac10 | - | All | All | All |
| Hardware | Tenda | Ac10 | - | All | All | All |
| Operating System | Tenda | Ac10 Firmware | 15.03.06.23_cn | All | All | All |
| Operating System | Tenda | Ac10 Firmware | 15.03.06.23_cn | All | All | All |
| Hardware | Tenda | Ac15 | - | All | All | All |
| Hardware | Tenda | Ac15 | - | All | All | All |
| Operating System | Tenda | Ac15 Firmware | 15.03.05.19_cn | All | All | All |
| Operating System | Tenda | Ac15 Firmware | 15.03.05.19_cn | All | All | All |
| Hardware | Tenda | Ac18 | - | All | All | All |
| Hardware | Tenda | Ac18 | - | All | All | All |
| Operating System | Tenda | Ac18 Firmware | 15.03.05.19(6318)_cn | All | All | All |
| Operating System | Tenda | Ac18 Firmware | 15.03.05.19\(6318\)_cn | All | All | All |
| Operating System | Tenda | Ac18 Firmware | 15.03.05.19\(6318\)_cn | All | All | All |
| Hardware | Tenda | Ac7 | - | All | All | All |
| Hardware | Tenda | Ac7 | - | All | All | All |
| Operating System | Tenda | Ac7 Firmware | 15.03.06.44_cn | All | All | All |
| Operating System | Tenda | Ac7 Firmware | 15.03.06.44_cn | All | All | All |
| Hardware | Tenda | Ac9 | - | All | All | All |
| Hardware | Tenda | Ac9 | - | All | All | All |
| Operating System | Tenda | Ac9 Firmware | 15.03.05.19(6318)_cn | All | All | All |
| Operating System | Tenda | Ac9 Firmware | 15.03.05.19\(6318\)_cn | All | All | All |
| Operating System | Tenda | Ac9 Firmware | 15.03.05.19\(6318\)_cn | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| iot/Tenda.md at master · zsjevilhex/iot · GitHub | MISC | github.com | Exploit, Third Party Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.