CVE-2018-8868

Summary

CVECVE-2018-8868
StatePUBLIC
Assigner[email protected]
Source PriorityCVE Program / NVD first with legacy fallback
Published2018-07-03 01:29:00 UTC
Updated2019-10-09 23:42:00 UTC
DescriptionMedtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can apply the other vulnerabilities within this advisory to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.

Risk And Classification

Problem Types: NVD-CWE-noinfo

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Hardware Medtronic 24950 Mycarelink Monitor - All All All
Hardware Medtronic 24950 Mycarelink Monitor - All All All
Operating System Medtronic 24950 Mycarelink Monitor Firmware - All All All
Operating System Medtronic 24950 Mycarelink Monitor Firmware - All All All
Hardware Medtronic 24952 Mycarelink Monitor - All All All
Hardware Medtronic 24952 Mycarelink Monitor - All All All
Operating System Medtronic 24952 Mycarelink Monitor Firmware - All All All
Operating System Medtronic 24952 Mycarelink Monitor Firmware - All All All

References

ReferenceSourceLinkTags
Medtronic MyCareLink Patient Monitor | CISA MISC ics-cert.us-cert.gov Third Party Advisory, US Government Resource
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis
© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

CVE.report and Source URL Uptime Status status.cve.report