CVE-2019-7479
Summary
| CVE | CVE-2019-7479 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2019-12-31 02:15:00 UTC |
| Updated | 2020-10-09 13:37:00 UTC |
| Description | A vulnerability in SonicOS allow authenticated read-only admin can elevate permissions to configuration mode. This vulnerability affected SonicOS Gen 5 version 5.9.1.12-4o and earlier, Gen 6 version 6.2.7.4-32n, 6.5.1.4-4n, 6.5.2.3-4n, 6.5.3.3-3n, 6.2.7.10-3n, 6.4.1.0-3n, 6.5.3.3-3n, 6.5.1.9-4n and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V). |
Risk And Classification
Problem Types: CWE-269
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Operating System | Sonicwall | Sonicos | 6.2.7.10-3n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.2.7.4-32n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.4.1.0-3n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.5.1.4-4n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.5.1.9-4n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.5.2.3-4n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.5.3.3-3n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.2.7.10-3n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.2.7.4-32n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.4.1.0-3n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.5.1.4-4n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.5.1.9-4n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.5.2.3-4n | All | All | All |
| Operating System | Sonicwall | Sonicos | 6.5.3.3-3n | All | All | All |
| Operating System | Sonicwall | Sonicos | All | All | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | All | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | rc363 | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | rc366 | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | rc367 | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | rc368 | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | All | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | rc363 | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | rc366 | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | rc367 | All | All |
| Operating System | Sonicwall | Sonicosv | 6.5.0.2.8v | rc368 | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Security Advisory | CONFIRM | psirt.global.sonicwall.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.