CVE-2020-10265
Summary
| CVE | CVE-2020-10265 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2020-04-06 12:15:00 UTC |
| Updated | 2020-04-06 23:14:00 UTC |
| Description | Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization. |
Risk And Classification
Problem Types: CWE-306
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Universal-robots | Ur10 | - | All | All | All |
| Hardware | Universal-robots | Ur10 | - | All | All | All |
| Hardware | Universal-robots | Ur10e | - | All | All | All |
| Hardware | Universal-robots | Ur10e | - | All | All | All |
| Hardware | Universal-robots | Ur3 | - | All | All | All |
| Hardware | Universal-robots | Ur3 | - | All | All | All |
| Hardware | Universal-robots | Ur3e | - | All | All | All |
| Hardware | Universal-robots | Ur3e | - | All | All | All |
| Hardware | Universal-robots | Ur5 | - | All | All | All |
| Hardware | Universal-robots | Ur5 | - | All | All | All |
| Hardware | Universal-robots | Ur5e | - | All | All | All |
| Hardware | Universal-robots | Ur5e | - | All | All | All |
| Application | Universal-robots | Ur Software | All | All | All | All |
| Application | Universal-robots | Ur Software | All | All | All | All |
| Application | Universal-robots | Ur Software | All | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Real-Time Data Exchange (RTDE) Guide - 22229 | CONFIRM | www.universal-robots.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
| Organization | Published | Contributor | Statement |
|---|---|---|---|
| Universal Robots | 2022-04-12 | Grzegorz Zieba | Software version 5.10 brings improvements to usability and configurability of Secure Shell Protocol (SSH), such that tunneling can be used to secure primary, secondary, RT, RTDE, DashBoard server and other interfaces. Universal Robots recommends that all users use SSH tunneling to access these interfaces in applications requiring authentication and encryption. Additionally, SW version 5.10 includes a built-in configurable firewall, allowing fine-grained restrictions of remote access, and number of other security improvements. Universal Robots (UR) recommends always using the latest UR software, as security improvements will be rolled out continuously. CB2 and CB3 cobots are designed to be operating in factory networks where security relies on boundary protection (firewalls) and trusted clients on the network. They must only be connected to trusted networks and operated by authorized personnel. |
Discovery Credit
LEGACY: Bernhard Dieber, Benjamin Breiling (and many others)