CVE-2020-28209
Summary
| CVE | CVE-2020-28209 |
|---|---|
| State | PUBLISHED |
| Assigner | schneider |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2020-11-19 22:15:13 UTC |
| Updated | 2026-05-28 21:16:25 UTC |
| Description | A CWE-428 Windows Unquoted Search Path vulnerability exists in EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 that could cause any local Windows user who has write permission on at least one of the subfolders of the Connect Agent service binary path, being able to gain the privilege of the user who started the service. By default, the Enterprise Server and Enterprise Central is always installed at a location requiring Administrator privileges so the vulnerability is only valid if the application has been installed on a non-secure location. |
Risk And Classification
Primary CVSS: v3.1 7 HIGH from [email protected]
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS: 0.000680000 probability, percentile 0.210010000 (date 2026-06-02)
Problem Types: CWE-428 | CWE-428 CWE-428 Windows Unquoted Search Path
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Primary | 7 | HIGH | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | ADP | DECLARED | 7 | HIGH | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | 134c704f-9b21-4f2e-91b3-4a467353bcc0 | Secondary | 7 | HIGH | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H |
| 2.0 | [email protected] | Primary | 4.4 | AV:L/AC:M/Au:N/C:P/I:P/A:P |
CVSS v3.1 Breakdown
Attack Vector
LocalAttack Complexity
HighPrivileges Required
LowUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS v2.0 Breakdown
Access Vector
LocalAccess Complexity
MediumAuthentication
NoneConfidentiality
PartialIntegrity
PartialAvailability
PartialAV:L/AC:M/Au:N/C:P/I:P/A:P
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Operating System | Microsoft | Windows | - | All | All | All |
| Application | Schneider-electric | Enterprise Server Installer | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Na | EcoStruxure Building Operation Enterprise Server Installer V1.9 - V3.1 And Enterprise Central Installer V2.0 - V3.1 | affected EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| Security Notification - EcoStruxure™ Building Operation (EBO) | Schneider Electric | af854a3a-2127-422b-91ae-364da2661108 | www.se.com | Patch, Product, Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.