CVE-2020-36166

Summary

CVECVE-2020-36166
StatePUBLIC
Assigner[email protected]
Source PriorityCVE Program / NVD first with legacy fallback
Published2021-01-06 01:15:00 UTC
Updated2021-01-12 19:22:00 UTC
DescriptionAn issue was discovered in Veritas InfoScale 7.x through 7.4.2 on Windows, Storage Foundation through 6.1 on Windows, Storage Foundation HA through 6.1 on Windows, and InfoScale Operations Manager (aka VIOM) Windows Management Server 7.x through 7.4.2. On start-up, it loads the OpenSSL library from \usr\local\ssl. This library attempts to load the \usr\local\ssl\openssl.cnf configuration file, which may not exist. On Windows systems, this path could translate to <drive>:\usr\local\ssl\openssl.cnf, where <drive> could be the default Windows installation drive such as C:\ or the drive where a Veritas product is installed. By default, on Windows systems, users can create directories under any top-level directory. A low privileged user can create a <drive>:\usr\local\ssl\openssl.cnf configuration file to load a malicious OpenSSL engine, resulting in arbitrary code execution as SYSTEM when the service starts. This gives the attacker administrator access on the system, allowing the attacker (by default) to access all data, access all installed applications, etc.

Risk And Classification

Problem Types: NVD-CWE-noinfo

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Operating System Microsoft Windows - All All All
Operating System Microsoft Windows - All All All
Application Veritas Infoscale All All All All
Application Veritas Infoscale Operations Manager All All All All
Application Veritas Storage Foundation All All All All
Application Veritas Storage Foundation And High Availability All All All All

References

ReferenceSourceLinkTags
InfoScale OpenSSL advisory | Veritas™ MISC www.veritas.com Vendor Advisory
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis
© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.