DescriptionA CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.

Risk And Classification

Problem Types: CWE-74

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Application Schneider-electric Ecostruxure Machine Expert All All All All
Hardware Schneider-electric Modicon M100 - All All All
Operating System Schneider-electric Modicon M100 Firmware All All All All
Hardware Schneider-electric Modicon M200 - All All All
Operating System Schneider-electric Modicon M200 Firmware All All All All
Hardware Schneider-electric Modicon M221 - All All All
Operating System Schneider-electric Modicon M221 Firmware All All All All
Application Schneider-electric Somachine Basic All All All All
Application Se Ecostruxure Machine Expert All All All All
Application Se Ecostruxure Machine Expert All All All All
Hardware Se Modicon M100 - All All All
Hardware Se Modicon M100 - All All All
Operating System Se Modicon M100 Firmware All All All All
Operating System Se Modicon M100 Firmware All All All All
Hardware Se Modicon M200 - All All All
Hardware Se Modicon M200 - All All All
Operating System Se Modicon M200 Firmware All All All All
Operating System Se Modicon M200 Firmware All All All All
Hardware Se Modicon M221 - All All All
Hardware Se Modicon M221 - All All All
Operating System Se Modicon M221 Firmware All All All All
Operating System Se Modicon M221 Firmware All All All All
Application Se Somachine Basic All All All All
Application Se Somachine Basic All All All All

References

ReferenceSourceLinkTags
Security Notification - Modicon M100/M200/M221 controllers, SoMachine Basic and EcoStruxure Machine Expert | Schneider Electric MISC www.se.com Patch, Vendor Advisory
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Legacy QID Mappings

  • 591019 Schneider Electric Modicon M100/M200/M221 controllers Vulnerability (SEVD-2020-105-01)
© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

CVE.report and Source URL Uptime Status status.cve.report