Certain versions of Sinumerik Analyse Mycondition from Siemens contain the following vulnerability:
A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.
- CVE-2021-31892 has been assigned by
productc[email protected] to track the vulnerability - currently rated as HIGH severity.
CVSS3 Score: 7.4 - HIGH
Attack Vector ⓘ |
Attack Complexity |
Privileges Required |
User Interaction |
---|---|---|---|
NETWORK | HIGH | NONE | NONE |
Scope | Confidentiality Impact |
Integrity Impact |
Availability Impact |
UNCHANGED | HIGH | HIGH | NONE |
CVSS2 Score: 5.8 - MEDIUM
Access Vector ⓘ |
Access Complexity |
Authentication |
---|---|---|
NETWORK | MEDIUM | NONE |
Confidentiality Impact |
Integrity Impact |
Availability Impact |
PARTIAL | PARTIAL | NONE |
CVE References
Description | Tags ⓘ | Link |
---|---|---|
cert-portal.siemens.com application/pdf |
![]() | |
Siemens SINUMERIK Integrate Operate Client | CISA | us-cert.cisa.gov text/html |
![]() |
Known Affected Configurations (CPE V2.3)
- cpe:2.3:h:siemens:sinumerik_analyse_mycondition:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_analyse_mycondition_firmware:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_analyze_myperformance:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_analyze_myperformance_firmware:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_integrate_client:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_integrate_client_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_integrate_for_production:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_integrate_for_production_firmware:5.1:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_integrate_for_production_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_manage_mymachines:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_manage_mymachines_firmware:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_manage_myprograms:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_manage_myprograms_firmware:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_manage_myresources:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_manage_myresources_firmware:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_manage_mytools:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_manage_mytools_firmware:-:*:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_operate:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:*:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp1:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp2:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp3:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp4:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp5:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp6:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp7:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_1:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_2:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_3:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_4:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_5:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_6:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:-:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_1:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_2:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_3:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_4:*:*:*:*:*:*:
- cpe:2.3:h:siemens:sinumerik_optimize_myprogramming:-:*:*:*:*:*:*:*:
- cpe:2.3:o:siemens:sinumerik_optimize_myprogramming_firmware:-:*:*:*:*:*:*:*:
Social Mentions
Source | Title | Posted (UTC) |
---|---|---|
![]() |
CVE-2021-31892 : A vulnerability has been identified in SINUMERIK Analyse MyCondition All versions , SINUMERIK Ana… twitter.com/i/web/status/1… | 2021-07-13 11:24:59 |
![]() |
CVE-2021-31892 | 2021-07-13 11:41:49 |