CVE-2021-40359
Summary
| CVE | CVE-2021-40359 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2021-11-09 12:15:00 UTC |
| Updated | 2023-04-11 10:15:00 UTC |
| Description | A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. |
Risk And Classification
Problem Types: CWE-22
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Siemens | Simaticpcs 7 | All | All | All | All |
| Application | Siemens | Simaticpcs 7 | 9.1 | - | All | All |
| Application | Siemens | Simaticpcs 7 | All | All | All | All |
| Application | Siemens | Simatic Batch | 8.2 | - | All | All |
| Application | Siemens | Simatic Batch | 8.2 | upd_9 | All | All |
| Application | Siemens | Simatic Batch | 9.0 | - | All | All |
| Application | Siemens | Simatic Batch | 9.0 | sp1 | All | All |
| Application | Siemens | Simatic Batch | 9.0 | sp1_update_1 | All | All |
| Application | Siemens | Simatic Batch | 9.0 | sp1_update_2 | All | All |
| Application | Siemens | Simatic Batch | 9.0 | sp1_update_3 | All | All |
| Application | Siemens | Simatic Batch | 9.0 | sp1_update_4 | All | All |
| Application | Siemens | Simatic Batch | 9.1 | - | All | All |
| Application | Siemens | Simatic Net Pc | 14 | - | All | All |
| Application | Siemens | Simatic Net Pc | 15 | - | All | All |
| Application | Siemens | Simatic Net Pc | 16 | - | All | All |
| Application | Siemens | Simatic Net Pc | 16 | update1 | All | All |
| Application | Siemens | Simatic Net Pc | 17 | - | All | All |
| Application | Siemens | Simatic Pcs 7 | 9.0 | - | All | All |
| Application | Siemens | Simatic Pcs 7 | 9.1 | All | All | All |
| Application | Siemens | Simatic Pcs 7 | All | All | All | All |
| Application | Siemens | Simatic Route Control | 8.2 | All | All | All |
| Application | Siemens | Simatic Route Control | 9.0 | - | All | All |
| Application | Siemens | Simatic Route Control | 9.1 | - | All | All |
| Application | Siemens | Simatic Wincc | 15 | All | All | All |
| Application | Siemens | Simatic Wincc | 15 | - | All | All |
| Application | Siemens | Simatic Wincc | 16 | All | All | All |
| Application | Siemens | Simatic Wincc | 16 | - | All | All |
| Application | Siemens | Simatic Wincc | 16 | update1 | All | All |
| Application | Siemens | Simatic Wincc | 16 | update2 | All | All |
| Application | Siemens | Simatic Wincc | 16 | update3 | All | All |
| Application | Siemens | Simatic Wincc | 16 | update4 | All | All |
| Application | Siemens | Simatic Wincc | 17 | All | All | All |
| Application | Siemens | Simatic Wincc | 17 | - | All | All |
| Application | Siemens | Simatic Wincc | 17 | update1 | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | All | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | - | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | sp1 | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | sp1_update1 | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | sp1_update2 | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | sp2 | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | sp2_update1 | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | sp2_update2 | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | sp2_update3 | All | All |
| Application | Siemens | Simatic Wincc | 7.5 | sp2_update4 | All | All |
| Application | Siemens | Simatic Wincc | All | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf | MISC | cert-portal.siemens.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
Legacy QID Mappings
- 590822 Siemens SIMATIC WinCC (Update B) Multiple Vulnerabilities (ICSA-21-315-03)