CVE-2022-24055
Summary
| CVE | CVE-2022-24055 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2022-02-18 20:15:00 UTC |
| Updated | 2022-02-24 21:52:00 UTC |
| Description | This vulnerability allows remote attackers to disclose sensitive information on affected installations of Sante DICOM Viewer Pro 11.8.7.0. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of GIF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-14972. |
Risk And Classification
Problem Types: CWE-125
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Santesoft | Dicom Viewer Pro | 11.8.7 | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| ZDI-22-247 | Zero Day Initiative | MISC | www.zerodayinitiative.com | Third Party Advisory, VDB Entry |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.