CVE-2022-36360
Summary
| CVE | CVE-2022-36360 |
|---|---|
| State | PUBLIC |
| Assigner | [email protected] |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2022-10-11 11:15:00 UTC |
| Updated | 2023-07-21 20:06:00 UTC |
| Description | A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker to manipulate a firmware update and flash it to the device. |
Risk And Classification
Problem Types: CWE-345 | CWE-354
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Siemens | Logo!8 Bm | - | All | All | All |
| Hardware | Siemens | Logo!8 Bm Fs-05 | - | All | All | All |
| Operating System | Siemens | Logo!8 Bm Fs-05 Firmware | All | All | All | All |
| Operating System | Siemens | Logo! 8 Bm Firmware | All | All | All | All |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| cert-portal.siemens.com/productcert/pdf/ssa-928782.pdf | MISC | cert-portal.siemens.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
Legacy QID Mappings
- 591260 Siemens LOGO! Firmware Authenticity Vulnerability (ICSA-22-286-01, SSA-928782)