CVE-2023-23447
Summary
| CVE | CVE-2023-23447 |
|---|---|
| State | PUBLISHED |
| Assigner | SICK AG |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2023-05-15 11:15:09 UTC |
| Updated | 2026-06-01 13:16:23 UTC |
| Description | Uncontrolled Resource Consumption in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to influence the availability of the webserver by invocing several open file requests via the REST interface. |
Risk And Classification
Primary CVSS: v3.1 7.5 HIGH from [email protected]
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS: 0.007760000 probability, percentile 0.739920000 (date 2026-06-04)
Problem Types: CWE-400 | CWE-400 CWE-400 Uncontrolled Resource Consumption
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Primary | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 3.1 | [email protected] | Secondary | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 3.1 | CNA | CVSS | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
NoneIntegrity
NoneAvailability
HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Sick | Ftmg-esd15axx | - | All | All | All |
| Operating System | Sick | Ftmg-esd15axx Firmware | All | All | All | All |
| Hardware | Sick | Ftmg-esd20axx | - | All | All | All |
| Operating System | Sick | Ftmg-esd20axx Firmware | All | All | All | All |
| Hardware | Sick | Ftmg-esd25axx | - | All | All | All |
| Operating System | Sick | Ftmg-esd25axx Firmware | All | All | All | All |
| Hardware | Sick | Ftmg-esn40sxx | - | All | All | All |
| Operating System | Sick | Ftmg-esn40sxx Firmware | All | All | All | All |
| Hardware | Sick | Ftmg-esn50sxx | - | All | All | All |
| Operating System | Sick | Ftmg-esn50sxx Firmware | All | All | All | All |
| Hardware | Sick | Ftmg-esr40sxx | - | All | All | All |
| Operating System | Sick | Ftmg-esr40sxx Firmware | All | All | All | All |
| Hardware | Sick | Ftmg-esr50sxx | - | All | All | All |
| Operating System | Sick | Ftmg-esr50sxx Firmware | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | SICK AG | SICK FTMG-ESD15AXX AIR FLOW SENSOR | affected v3.0.0.131.Release * | Not specified |
| CNA | SICK AG | SICK FTMG-ESD20AXX AIR FLOW SENSOR | affected v3.0.0.131.Release * | Not specified |
| CNA | SICK AG | SICK FTMG-ESD25AXX AIR FLOW SENSOR | affected v3.0.0.131.Release * | Not specified |
| CNA | SICK AG | SICK FTMG-ESN40SXX AIR FLOW SENSOR | affected v3.0.0.131.Release * | Not specified |
| CNA | SICK AG | SICK FTMG-ESN50SXX AIR FLOW SENSOR | affected v3.0.0.131.Release * | Not specified |
| CNA | SICK AG | SICK FTMG-ESR40SXX AIR FLOW SENSOR | affected v3.0.0.131.Release * | Not specified |
| CNA | SICK AG | SICK FTMG-ESR50SXX AIR FLOW SENSOR | affected v3.0.0.131.Release * | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| The SICK Product Security Incident Response Team (SICK PSIRT) | SICK | af854a3a-2127-422b-91ae-364da2661108 | sick.com | Vendor Advisory |
| sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf | af854a3a-2127-422b-91ae-364da2661108 | sick.com | Vendor Advisory |
| sick.com/.well-known/csaf/white/2023/sca-2023-0004.json | af854a3a-2127-422b-91ae-364da2661108 | sick.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
Additional Advisory Data
Solutions
CNA: SICK has released a new major version v3.0.0.131.Release of the SICK FTMg firmware and recommends updating to the newest version.