CVE-2023-35698
Summary
| CVE | CVE-2023-35698 |
|---|---|
| State | PUBLISHED |
| Assigner | SICK AG |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2023-07-10 16:15:52 UTC |
| Updated | 2026-06-01 13:16:24 UTC |
| Description | Observable Response Discrepancy in the SICK ICR890-4 could allow a remote attacker to identify valid usernames for the FTP server from the response given during a failed login attempt. |
Risk And Classification
Primary CVSS: v3.1 5.3 MEDIUM from [email protected]
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
EPSS: 0.002900000 probability, percentile 0.526640000 (date 2026-06-04)
Problem Types: CWE-204 | CWE-203 | CWE-204 CWE-204 Observable Response Discrepancy
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Primary | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| 3.1 | [email protected] | Secondary | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| 3.1 | CNA | CVSS | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
LowIntegrity
NoneAvailability
NoneCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Sick | Icr890-4 | - | All | All | All |
| Operating System | Sick | Icr890-4 Firmware | All | All | All | All |
Vendor Declared Affected Products
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| The SICK Product Security Incident Response Team (SICK PSIRT) | SICK | af854a3a-2127-422b-91ae-364da2661108 | sick.com | Product |
| sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf | af854a3a-2127-422b-91ae-364da2661108 | sick.com | Vendor Advisory |
| sick.com/.well-known/csaf/white/2023/sca-2023-0006.json | af854a3a-2127-422b-91ae-364da2661108 | sick.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
Additional Advisory Data
Solutions
CNA: The recommended solution is to update the firmware to a version >= V2.5.0 as soon as possible.
There are currently no legacy QID mappings associated with this CVE.