CVE-2023-35699

Summary

CVECVE-2023-35699
StatePUBLISHED
AssignerSICK AG
Source PriorityCVE Program / NVD first with legacy fallback
Published2023-07-10 16:15:52 UTC
Updated2026-06-01 13:16:24 UTC
DescriptionCleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card.

Risk And Classification

Primary CVSS: v3.1 4.6 MEDIUM from [email protected]

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

EPSS: 0.000520000 probability, percentile 0.165110000 (date 2026-06-03)

Problem Types: CWE-313 | CWE-312 | CWE-313 CWE-313 Cleartext Storage in a File or on Disk


VersionSourceTypeScoreSeverityVector
3.1[email protected]Primary4.6MEDIUMCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
3.1[email protected]Secondary5.3MEDIUMCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N
3.1CNACVSS5.3MEDIUMCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N

CVSS v3.1 Breakdown

Attack Vector
Physical
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Hardware Sick Icr890-4 - All All All
Operating System Sick Icr890-4 Firmware All All All All

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA SICK AG ICR890-4 affected 2.5.0 * Not specified

References

ReferenceSourceLinkTags
The SICK Product Security Incident Response Team (SICK PSIRT) | SICK af854a3a-2127-422b-91ae-364da2661108 sick.com Product
sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf af854a3a-2127-422b-91ae-364da2661108 sick.com Vendor Advisory
sick.com/.well-known/csaf/white/2023/sca-2023-0006.json af854a3a-2127-422b-91ae-364da2661108 sick.com Vendor Advisory
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Additional Advisory Data

Workarounds

CNA: Please make sure that you apply general security practices when operating the SICK ICR890- 4 like restricting physical access to the device. The following general security practices could mitigate the associated security risk.

© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report