CVE-2024-8751

Summary

CVECVE-2024-8751
StatePUBLISHED
AssignerSICK AG
Source PriorityCVE Program / NVD first with legacy fallback
Published2024-09-12 22:15:02 UTC
Updated2026-07-16 11:16:36 UTC
DescriptionA vulnerability allows a remote unauthenticated attacker to modify the prod uct’s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.

Risk And Classification

Primary CVSS: v3.1 7.5 HIGH from [email protected]

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

EPSS: 0.009260000 probability, percentile 0.567260000 (date 2026-07-22)

Problem Types: CWE-306 | CWE-306 CWE-306 Missing Authentication for Critical Function


VersionSourceTypeScoreSeverityVector
3.1[email protected]Secondary7.5HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
3.1CNACVSS7.5HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

CVSS v3.1 Breakdown

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Endress Hauser MSC800 affected V1.0 <=V4.25 custom Not specified
CNA Endress Hauser MSC800 affected S1.0 <=S2.93.19 custom Not specified
CNA Endress Hauser MARSIC200 affected all versions custom Not specified
CNA Endress Hauser MARSIC280 affected all versions custom Not specified
CNA Endress Hauser MARSIC300 affected all versions custom Not specified
CNA Endress Hauser MCS100FT affected all versions custom Not specified
CNA Endress Hauser MCS200HW affected all versions custom Not specified
CNA Endress Hauser MCS300P affected all versions custom Not specified
CNA Endress Hauser MERCEM300Z affected all versions custom Not specified
CNA Endress Hauser SAM800 affected all versions custom Not specified
CNA Endress Hauser SIPROCESS affected all versions custom Not specified
CNA Endress Hauser GMS800 affected all versions custom Not specified
CNA Endress Hauser GMS800 FIDOR affected all versions custom Not specified
CNA Endress Hauser GM32 affected all versions custom Not specified
CNA Endress Hauser VICOTEC320 affected all versions custom Not specified
CNA Endress Hauser MCU ETH-Service And Modbus-TCP Module affected all versions custom Not specified
CNA Endress Hauser FLPS affected all versions custom Not specified
CNA Endress Hauser MES1B BB Converter affected all versions custom Not specified
ADP Sick Msc800 Firmware affected 1.0 4.25 custom Not specified
ADP Sick Msc800 Firmware affected 1.0 s2.93.19 custom Not specified

References

ReferenceSourceLinkTags
www.sick.com/.well-known/csaf/white/2024/sca-2024-0002.json [email protected] www.sick.com
www.sick.com/.well-known/csaf/white/2024/sca-2024-0002.pdf [email protected] www.sick.com
www.first.org/cvss/calculator/3.1 [email protected] www.first.org
www.endress.com [email protected] www.endress.com
sick.com/psirt [email protected] sick.com
www.cisa.gov/resources-tools/resources/ics-recommended-practices [email protected] www.cisa.gov
www.sick.com/.well-known/csaf/white/2026/sca-2026-0009.json [email protected] www.sick.com
cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK... [email protected] cdn.sick.com
www.sick.com/.well-known/csaf/white/2026/sca-2026-0009.pdf [email protected] www.sick.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Additional Advisory Data

SourceTimeEvent
CNA2024-09-12T21:36:00.000Z1: Initial version
CNA2026-07-16T10:00:00.000Z2: Added more products

Solutions

CNA: For Endress+Hauser MSC800FT: Customers who use the version <=V4.25 are strongly recommended to upgrade to the latest release V4.26

CNA: For Endress+Hauser MSC800FT: Customers who use the version <=S2.93.19 are strongly recommended to upgrade to the latest release S2.93.20.

Workarounds

CNA: For Endress+Hauser MARSIC200, MARSIC280, MARSIC300, MCS100FT, MCS200HW, MCS300P, MERCEM300Z, SAM800, SIPROCESS, GMS800, GMS800 FIDOR, GM32, VICOTEC320, MCU ETH-Service and Modbus-TCP Module, FLPS, MES1B B&B Converter:  Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api