Semtech LR11xx Encrypted Firmware Disclosure

Summary

CVECVE-2025-14858
StatePUBLISHED
AssignerSWI
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-04-07 20:16:22 UTC
Updated2026-04-08 21:27:00 UTC
DescriptionThe Semtech LR11xx LoRa transceivers running early versions of firmware contains an information disclosure vulnerability in its firmware validation functionality. When a host issues a firmware validity check command via the SPI interface, the device decrypts the provided encrypted firmware package block-by-block to validate its integrity. However, the last decrypted firmware block remains uncleared in memory after the validation process completes. An attacker with access to the SPI interface can subsequently issue memory read commands to retrieve the decrypted firmware contents from this residual memory, effectively bypassing the firmware encryption protection mechanism. The attack requires physical access to the device's SPI interface.

Risk And Classification

Primary CVSS: v4.0 5.1 MEDIUM from [email protected]

CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:N/R:A/V:C/RE:M/U:X

EPSS: 0.000140000 probability, percentile 0.024850000 (date 2026-04-13)

Problem Types: CWE-226 | CWE-226 CWE-226 Sensitive Information in Resource Not Removed Before Reuse


VersionSourceTypeScoreSeverityVector
4.0[email protected]Secondary5.1MEDIUMCVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/C...
4.0CNACVSS5.1MEDIUMCVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/AU:N/...

CVSS v4.0 Breakdown

Attack Vector
Physical
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Confidentiality
High
Integrity
None
Availability
None
Sub Conf.
None
Sub Integrity
None
Sub Availability
None

CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:N/R:A/V:C/RE:M/U:X

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Semtech LR1110 affected TRX FW 0x0402 custom Not specified
CNA Semtech LR1120 affected TRX FW 0x0202 custom Not specified
CNA Semtech LR1121 affected TRX FW 0x0104 custom Not specified

References

ReferenceSourceLinkTags
www.semtech.com/company/security/security-bulletins/sem-psa-2026-001 [email protected] www.semtech.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Egor (radioegor146) Koleda, https://github.com/radioegor146 (en)

© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report