CVE-2025-1789

Summary

CVECVE-2025-1789
StatePUBLISHED
AssignerGenetec
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-02-24 20:27:42 UTC
Updated2026-04-26 18:49:06 UTC
DescriptionLocal privilege escalation in Genetec Update Service. An authenticated, low-privileged, Windows user could exploit this vulnerability to gain elevated privileges on the affected system.

Risk And Classification

Primary CVSS: v4.0 5.8 MEDIUM from [email protected]

CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:C/RE:X/U:X

EPSS: 0.000140000 probability, percentile 0.027610000 (date 2026-04-26)

Problem Types: CWE-276 | CWE-276 Incorrect Default Permissions


VersionSourceTypeScoreSeverityVector
4.0[email protected]Secondary5.8MEDIUMCVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/C...
4.0CNACVSS5.8MEDIUMCVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/C...
3.1[email protected]Primary7.8HIGHCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CVSS v4.0 Breakdown

Attack Vector
Local
Attack Complexity
High
Attack Requirements
Present
Privileges Required
Low
User Interaction
None
Confidentiality
High
Integrity
High
Availability
High
Sub Conf.
High
Sub Integrity
High
Sub Availability
High

CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:C/RE:X/U:X

CVSS v3.1 Breakdown

Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Application Genetec Genetec Update Service All All All All

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Genetec Inc. Genetec Update Service affected <2.10.600 semver Windows
CNA Genetec Inc. Genetec Update Service unaffected >=2.10.600 semver Windows

References

ReferenceSourceLinkTags
techdocs.genetec.com/r/en-US/Security-Updates-for-GenetecTM-Update-Service-2.10/Re... [email protected] techdocs.genetec.com Issue Tracking, Vendor Advisory
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Rutger Flohil (en)

Additional Advisory Data

Solutions

CNA: This issue is fixed in Genetec Update Service 2.10.600 and all later versions. Internet connected Genetec Update Service will automatically update themselves.

© CVE.report 2026 |

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.