CVE-2025-25249

Summary

CVECVE-2025-25249
StatePUBLISHED
Assignerfortinet
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-01-13 17:15:56 UTC
Updated2026-09-10 12:47:59 UTC
DescriptionA heap-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0.0 through 7.0.17, FortiOS 6.4 all versions, FortiSwitchManager 7.2.0 through 7.2.6, FortiSwitchManager 7.0.0 through 7.0.5 allows attacker to execute unauthorized code or commands via specially crafted packets

Risk And Classification

Primary CVSS: v3.1 9.8 CRITICAL from [email protected]

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

EPSS: 0.024030000 probability, percentile 0.833060000 (date 2026-09-20)

CISA KEV: Listed on 2026-09-09; due 2026-09-12; ransomware use Unknown

Problem Types: CWE-122 | CWE-787 | CWE-122 Execute unauthorized code or commands


VersionSourceTypeScoreSeverityVector
3.1[email protected]Primary9.8CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
3.1[email protected]Secondary8.1HIGHCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
3.1CNACVSS7.4HIGHCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:W/RC:C

CVSS v3.1 Breakdown

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CISA Known Exploited Vulnerability

VendorFortinet
ProductMultiple Products
NameFortinet Multiple Products Heap-based Buffer Overflow Vulnerability
Required ActionApply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Noteshttps://fortiguard.fortinet.com/psirt/FG-IR-25-084 ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ; https://nvd.nist.gov/vuln/detail/CVE-2025-25249

NVD Known Affected Configurations (CPE 2.3)

TypeVendorProductVersionUpdateEditionLanguage
Operating System Fortinet Fortios All All All All

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Fortinet FortiSwitchManager affected 7.2.2 7.2.5 semver Not specified
CNA Fortinet FortiOS affected 7.6.0 7.6.2 semver Not specified
CNA Fortinet FortiOS affected 7.4.0 7.4.7 semver Not specified
CNA Fortinet FortiOS affected 7.2.4 7.2.11 semver Not specified
ADP Siemens RUGGEDCOM APE1808 affected * custom Not specified

References

ReferenceSourceLinkTags
cert-portal.siemens.com/productcert/html/ssa-864900.html 0b142b55-0307-4c5a-b3c9-f314f3fb7c5e cert-portal.siemens.com Third Party Advisory
socradar.io/blog/cve-2025-25249-pivotc2-fortigate-rat 134c704f-9b21-4f2e-91b3-4a467353bcc0 socradar.io Exploit, Third Party Advisory
www.cisa.gov/known-exploited-vulnerabilities-catalog 134c704f-9b21-4f2e-91b3-4a467353bcc0 www.cisa.gov US Government Resource
fortiguard.fortinet.com/psirt/FG-IR-25-084 [email protected] fortiguard.fortinet.com Vendor Advisory, Mitigation
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis
CISA Known Exploited Vulnerabilities catalog CISA www.cisa.gov kev

Additional Advisory Data

Solutions

CNA: Upgrade to FortiSwitchManager version 7.2.7 or above Upgrade to FortiSwitchManager version 7.0.6 or above Fortinet remediated this issue in FortiSASE version 25.2.c and hence customers do not need to perform any action. Fortinet remediated this issue in FortiSASE version 25.1.b and hence customers do not need to perform any action. Upgrade to upcoming FortiOS version 8.0.0 or above Upgrade to FortiOS version 7.6.4 or above Upgrade to FortiOS version 7.4.9 or above Upgrade to FortiOS version 7.2.12 or above Upgrade to FortiOS version 7.0.18 or above

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report