Reflected XSS vulnerability in pxc_portSecCfg.php
Summary
| CVE | CVE-2025-41746 |
|---|---|
| State | PUBLISHED |
| Assigner | CERTVDE |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2025-12-09 16:17:49 UTC |
| Updated | 2026-09-30 20:10:00 UTC |
| Description | An XSS vulnerability in pxc_portSecCfg.php can be used by an unauthenticated remote attacker to trick an authenticated user to send a manipulated POST request to the device in order to change parameters available via web based management (WBM). The vulnerability does not provide access to system-level resources such as operating system internals or privileged functions. Access is limited to device configuration parameters that are available in the context of the web application. The session cookie is secured by the httpOnly Flag. Therefore an attacker is not able to take over the session of an authenticated user. |
Risk And Classification
Primary CVSS: v3.1 7.1 HIGH from [email protected]
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L
EPSS: 0.097650000 probability, percentile 0.953960000 (date 2026-10-02)
Problem Types: CWE-79 | CWE-79 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Secondary | 7.1 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L |
| 3.1 | CNA | CVSS | 7.1 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L |
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
NoneUser Interaction
RequiredScope
ChangedConfidentiality
LowIntegrity
LowAvailability
LowCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L
NVD Known Affected Configurations (CPE 2.3)
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Phoenix Contact | FL SWITCH 2005 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2008 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2016 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2105 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2108 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2116 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2204-2TC-2SFX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2205 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2206-2FX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2206-2FX SM | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2206-2FX SM ST | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2206-2FX ST | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2206-2SFX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2206-2SFX PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2206C-2FX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2207-FX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2207-FX SM | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2208 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2208 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2208C | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2212-2TC-2SFX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2214-2FX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2214-2FX SM | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2214-2SFX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2214-2SFX PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2216 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2216 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2304-2GC-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2306-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2306-2SFP PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2308 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2308 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2312-2GC-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2314-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2314-2SFP PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2316 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2316 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2404-2TC-2SFX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2406-2SFX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2406-2SFX PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2408 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2408 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2412-2TC-2SFX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2414-2SFX | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2414-2SFX PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2416 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2416 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2504-2GC-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2506-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2506-2SFP PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2508 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2508 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2512-2GC-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2514-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2514-2SFP PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2516 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2516 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2608 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2608 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2708 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2708 PN | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2303-8SP1 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL NAT 2008 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL NAT 2208 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL NAT 2304-2GC-2SFP | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2008F | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2316/K1 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2506-2SFP/K1 | affected 0.0.0 3.50 semver | Not specified |
| CNA | Phoenix Contact | FL SWITCH 2508/K1 | affected 0.0.0 3.50 semver | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| certvde.com/de/advisories/VDE-2025-071 | [email protected] | certvde.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: D. Blagojevic, S. Dietz, F. Koroknai, T. Weber from CyberDanube (en)
There are currently no legacy QID mappings associated with this CVE.