| Description | Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer. |
Risk And Classification
Primary CVSS: v3.1 8.2 HIGH from [email protected]
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Problem Types: CWE-272 | CWE-272 CWE-272 Least Privilege Violation
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Secondary | 8.2 | HIGH | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
| 3.1 | CNA | DECLARED | 8.2 | HIGH | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
CVSS v3.1 Breakdown
Attack Vector
LocalAttack Complexity
LowPrivileges Required
HighUser Interaction
NoneScope
ChangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Wibu | CodeMeter | affected 8.30a custom | Not specified |
| ADP | Siemens | Desigo CC Family V5.0 | affected * custom | Not specified |
| ADP | Siemens | Desigo CC Family V5.1 | affected * custom | Not specified |
| ADP | Siemens | Desigo CC Family V6 | affected * custom | Not specified |
| ADP | Siemens | Desigo CC Family V7 | affected * custom | Not specified |
| ADP | Siemens | Desigo CC Family V8 | affected V8.0 QU2 custom | Not specified |
| ADP | Siemens | SENTRON Powermanager V5 | affected * custom | Not specified |
| ADP | Siemens | SENTRON Powermanager V6 | affected * custom | Not specified |
| ADP | Siemens | SENTRON Powermanager V7 | affected * custom | Not specified |
| ADP | Siemens | SENTRON Powermanager V8 | affected V8.0 QU2 custom | Not specified |
| ADP | Siemens | SIMATIC PDM Maintenance Station V5.0 | affected V5.0 SP2 custom | Not specified |
| ADP | Siemens | SIMATIC WinCC OA V3.18 | affected V3.18 P032 custom | Not specified |
| ADP | Siemens | SIMATIC WinCC OA V3.19 | affected V3.19 P020 custom | Not specified |
| ADP | Siemens | SIMATIC WinCC OA V3.20 | affected V3.20 P008 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| cert-portal.siemens.com/productcert/html/ssa-331739.html | 0b142b55-0307-4c5a-b3c9-f314f3fb7c5e | cert-portal.siemens.com | |
| cert-portal.siemens.com/productcert/html/ssa-201595.html | 0b142b55-0307-4c5a-b3c9-f314f3fb7c5e | cert-portal.siemens.com | |
| www.wibu.com/support/security-advisories/wibu-100120.html | [email protected] | www.wibu.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.