CVE-2025-53700
Summary
| CVE | CVE-2025-53700 |
|---|---|
| State | PUBLISHED |
| Assigner | jci |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-11-13 22:17:18 UTC |
| Updated | 2026-11-16 23:17:12 UTC |
| Description | CWE‑922 Insecure Storage of Sensitive Information vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑15 File Manipulation. This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02. |
Risk And Classification
Primary CVSS: v4.0 6.3 MEDIUM from [email protected]
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.001320000 probability, percentile 0.028570000 (date 2026-11-15)
Problem Types: CWE-922 | CWE‑922 Insecure Storage of Sensitive Information | CWE-922 CWE-922 Insecure Storage of Sensitive Information
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 6.3 | MEDIUM | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/C... |
| 4.0 | CNA | CVSS | 6.3 | MEDIUM | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H |
CVSS v4.0 Breakdown
Attack Vector
LocalAttack Complexity
LowAttack Requirements
NonePrivileges Required
LowUser Interaction
NoneConfidentiality
NoneIntegrity
NoneAvailability
NoneSub Conf.
HighSub Integrity
HighSub Availability
HighCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Johnson Controls | ISTAR Ultra | affected 6.9.2.CU02 custom | Not specified |
| CNA | Johnson Controls | ISTAR Ultra SE | affected 6.9.2.CU02 custom | Not specified |
| CNA | Johnson Controls | ISTAR Ultra G2 | affected 6.9.2.CU02 custom | Not specified |
| CNA | Johnson Controls | ISTAR Ultra G2 SE | affected 6.9.2.CU02 custom | Not specified |
| CNA | Johnson Controls | ISTAR Edge G2 | affected 6.9.2.CU02 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories | [email protected] | www.johnsoncontrols.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.