Reflected Cross-Site Scripting (XSS) in CGM CLININET
Summary
| CVE | CVE-2025-58403 |
|---|---|
| State | PUBLISHED |
| Assigner | CERT-PL |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-10-23 09:17:05 UTC |
| Updated | 2026-10-26 21:10:00 UTC |
| Description | CGM CLININET is vulnerable to Reflected Cross-Site Scripting (XSS) due to improper neutralization of user-supplied data. A remote unauthenticated attacker can craft a malicious URL containing JavaScript or HTML code, which is executed in the victim's browser when the URL is visited, allowing the attacker to steal session cookies and perform actions on behalf of the victim within the application. The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable. |
Risk And Classification
Primary CVSS: v4.0 5.1 MEDIUM from [email protected]
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.005000000 probability, percentile 0.425730000 (date 2026-10-26)
Problem Types: CWE-79 | CWE-79 CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 5.1 | MEDIUM | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 5.1 | MEDIUM | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N |
CVSS v4.0 Breakdown
Attack Vector
NetworkAttack Complexity
LowAttack Requirements
NonePrivileges Required
NoneUser Interaction
ActiveConfidentiality
NoneIntegrity
NoneAvailability
NoneSub Conf.
LowSub Integrity
LowSub Availability
NoneCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | CGM | CGM CLININET | affected 2025.MS3 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.cgm.com/pol_pl/products/szpital/cgm-clininet.html | [email protected] | www.cgm.com | |
| cert.pl/en/posts/2026/10/CVE-2025-30043 | [email protected] | cert.pl | |
| cert.pl/en/posts/2026/10/CVE-2025-58403 | MITRE | cert.pl | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.