Information Disclosure Through Stacktrace-/MQTT/Config/changeAll
Summary
| CVE | CVE-2025-58581 |
|---|---|
| State | PUBLISHED |
| Assigner | SICK AG |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2025-10-06 07:15:34 UTC |
| Updated | 2026-10-09 10:10:00 UTC |
| Description | When an error occurs in the application a full stacktrace is provided to the user. The stacktrace lists class and method names as well as other internal information. An attacker can thus obtain information about the technology used and the structure of the application. |
Risk And Classification
Primary CVSS: v3.1 4.3 MEDIUM from [email protected]
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
EPSS: 0.003330000 probability, percentile 0.245790000 (date 2026-10-11)
Problem Types: CWE-200 | NVD-CWE-noinfo | CWE-200 CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Secondary | 4.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N |
| 3.1 | CNA | CVSS | 4.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N |
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
LowUser Interaction
NoneScope
UnchangedConfidentiality
LowIntegrity
NoneAvailability
NoneCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Sick | Enterprise Analytics | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | SICK AG | Enterprise Analytics | affected all versions custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.first.org/cvss/calculator/3.1 | [email protected] | www.first.org | Not Applicable |
| www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.json | [email protected] | www.sick.com | Vendor Advisory |
| www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.pdf | [email protected] | www.sick.com | Vendor Advisory |
| sick.com/psirt | [email protected] | sick.com | Vendor Advisory |
| www.cisa.gov/resources-tools/resources/ics-recommended-practices | [email protected] | www.cisa.gov | US Government Resource |
| www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidel... | [email protected] | www.sick.com | Product |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
Additional Advisory Data
Workarounds
CNA: Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.
There are currently no legacy QID mappings associated with this CVE.