User Enumeration by excessive error output
Summary
| CVE | CVE-2025-58586 |
|---|---|
| State | PUBLISHED |
| Assigner | SICK AG |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2025-10-06 07:15:35 UTC |
| Updated | 2026-06-17 09:44:34 UTC |
| Description | For failed login attempts, the application returns different error messages depending on whether the login failed due to an incorrect password or a non-existing username. This allows an attacker to guess usernames until they find an existing one. |
Risk And Classification
Primary CVSS: v3.1 5.3 MEDIUM from [email protected]
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
EPSS: 0.003640000 probability, percentile 0.287190000 (date 2026-10-18)
Problem Types: CWE-204 | CWE-204 CWE-204 Observable Response Discrepancy
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Secondary | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| 3.1 | CNA | CVSS | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
CVSS v3.1 Breakdown
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Sick | Baggage Analytics | All | All | All | All |
| Application | Sick | Enterprise Analytics | All | All | All | All |
| Application | Sick | Logistic Diagnostic Analytics | All | All | All | All |
| Application | Sick | Package Analytics | All | All | All | All |
| Application | Sick | Tire Analytics | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | SICK AG | Baggage Analytics | affected 4.6.3 custom | Not specified |
| CNA | SICK AG | Tire Analytics | affected 4.6.3 custom | Not specified |
| CNA | SICK AG | Package Analytics | affected 4.6.3 custom | Not specified |
| CNA | SICK AG | Logistic Diagnostic Analytics | affected 4.6.3 custom | Not specified |
| CNA | SICK AG | Enterprise Analytics | affected all versions custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.first.org/cvss/calculator/3.1 | [email protected] | www.first.org | Not Applicable |
| www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.json | [email protected] | www.sick.com | Vendor Advisory |
| www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.pdf | [email protected] | www.sick.com | Vendor Advisory |
| sick.com/psirt | [email protected] | sick.com | Vendor Advisory |
| www.cisa.gov/resources-tools/resources/ics-recommended-practices | [email protected] | www.cisa.gov | US Government Resource |
| www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidel... | [email protected] | www.sick.com | Product |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Additional Advisory Data
Solutions
CNA: For Logistic Analytics Products: It is strongly recommended to update the product to version 4.6.3.
Workarounds
CNA: For Enterprise Analytics: Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.