RCE via the poller reload feature available only to user with high privilege
Summary
| CVE | CVE-2025-5946 |
|---|---|
| State | PUBLISHED |
| Assigner | Centreon |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2025-10-14 15:16:11 UTC |
| Updated | 2026-10-08 12:10:00 UTC |
| Description | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28. |
Risk And Classification
Primary CVSS: v3.1 7.2 HIGH from bd4443e6-1eef-43f3-9886-25fc9ceeaae7
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Problem Types: CWE-78 | CWE-78 CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | bd4443e6-1eef-43f3-9886-25fc9ceeaae7 | Secondary | 7.2 | HIGH | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | CNA | CVSS | 7.2 | HIGH | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
HighUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Centreon | Centreon Web | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Centreon | Infra Monitoring | affected 24.10.0 24.10.13 custom | Not specified |
| CNA | Centreon | Infra Monitoring | affected 24.04.0 24.04.18 custom | Not specified |
| CNA | Centreon | Infra Monitoring | affected 23.10.0 23.10.28 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| github.com/centreon/centreon/releases | bd4443e6-1eef-43f3-9886-25fc9ceeaae7 | github.com | Release Notes |
| thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5946-centreon-web-all-v... | bd4443e6-1eef-43f3-9886-25fc9ceeaae7 | thewatch.centreon.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: h00die-gr3y a.k.a. Hanko van Giessen (en)
There are currently no legacy QID mappings associated with this CVE.