Nanosystems Supremo before 5.0.2.3874 Improper TLS Certificate Validation
Summary
| CVE | CVE-2026-121624 |
|---|---|
| State | PUBLISHED |
| Assigner | VulnCheck |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-11-03 18:17:58 UTC |
| Updated | 2026-11-03 18:17:58 UTC |
| Description | Nanosystems Supremo for Windows and macOS before 5.0.2.3874 contains an improper certificate validation vulnerability that allows adjacent attackers to intercept TLS connections by presenting untrusted certificates. Attackers on the same network can terminate and relay the client's TLS session using self-signed certificates to read usernames, SHA-256 password hashes, and license codes. |
Risk And Classification
Primary CVSS: v4.0 7.6 HIGH from [email protected]
CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-295 | CWE-295 Improper Certificate Validation
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 7.6 | HIGH | CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 7.6 | HIGH | CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Primary | 6.8 | MEDIUM | CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N |
| 3.1 | CNA | CVSS | 6.8 | MEDIUM | CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N |
CVSS v4.0 Breakdown
Attack Vector
AdjacentAttack Complexity
HighAttack Requirements
PresentPrivileges Required
NoneUser Interaction
NoneConfidentiality
HighIntegrity
HighAvailability
NoneSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
AdjacentAttack Complexity
HighPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
NoneCVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Nanosystems | Supremo | affected 5.0.2.3874 custom | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.supremocontrol.com/changelog | [email protected] | www.supremocontrol.com | |
| pusi77.eu.org/blog/2026-11-03-supremo-tls-cve | [email protected] | pusi77.eu.org | |
| www.supremocontrol.com | [email protected] | www.supremocontrol.com | |
| www.vulncheck.com/advisories/nanosystems-supremo-before-5.0.2.3874-improper-tls... | [email protected] | www.vulncheck.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Andrea Pusineri (en)
There are currently no legacy QID mappings associated with this CVE.