Multiple vulnerabilities in Ghost Robotics' Vision 60
Summary
| CVE | CVE-2026-12990 |
|---|---|
| State | PUBLISHED |
| Assigner | INCIBE |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-07-27 13:16:52 UTC |
| Updated | 2026-07-27 20:32:11 UTC |
| Description | An access control vulnerability in the mobile app (APK v5.5.0) for Ghost Robotics' Vision 60 robot allows multiple simultaneous sessions to run without proper client validation or session integrity checks. An attacker with a modified version of the app can connect to the robot during an active, legitimate session. This allows the attacker to bypass control restrictions, intercept sensitive information (such as real-time video), and partially interact with the system unnoticed and without disconnecting the legitimate user, compromising confidentiality and operational security. |
Risk And Classification
Primary CVSS: v4.0 7.7 HIGH from [email protected]
CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.001310000 probability, percentile 0.030870000 (date 2026-07-29)
Problem Types: CWE-284 | CWE-284 CWE-284 Improper Access Control
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 7.7 | HIGH | CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 7.7 | HIGH | CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
CVSS v4.0 Breakdown
Attack Vector
AdjacentAttack Complexity
HighAttack Requirements
NonePrivileges Required
NoneUser Interaction
NoneConfidentiality
HighIntegrity
HighAvailability
HighSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Ghost Robotics | Vision 60 | affected 5.5.0 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-gho... | [email protected] | www.incibe.es | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Víctor Manuel Charro García, Adrián Campazas Vega and Claudia Álvarez Aparicio. (en)
Additional Advisory Data
Solutions
CNA: No solution has been reported at this time.
There are currently no legacy QID mappings associated with this CVE.