Denial of Service (DoS) through HTTP PubSub Channel Subscriptions in Splunk Enterprise

Summary

CVECVE-2026-131195
StatePUBLISHED
Assignercisco
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-11-19 20:17:31 UTC
Updated2026-11-19 20:17:31 UTC
DescriptionIn Splunk Enterprise versions below 10.4.5, 10.2.9, 10.0.12, and 9.4.17, an unauthenticated user could send repeated HTTP PubSub channel subscription requests that cause a Denial of Service (DoS) by permanently increasing memory usage until Splunk Enterprise exhausts available memory. The vulnerability affects instances that turn on the [pubsubsvr-http] stanza in server.conf because the HTTP PubSub broker does not release memory associated with a channel after the client disconnects.

Risk And Classification

Primary CVSS: v3.1 5.9 MEDIUM from [email protected]

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

Problem Types: CWE-401 | CWE-401 The software does not sufficiently track and release allocated memory after it has been used, which slowly consumes remaining memory.


VersionSourceTypeScoreSeverityVector
3.1[email protected]Primary5.9MEDIUMCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
3.1CNACVSS5.9MEDIUMCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

CVSS v3.1 Breakdown

Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Splunk Splunk Enterprise affected 10.4 10.4.5 custom Not specified
CNA Splunk Splunk Enterprise affected 10.2 10.2.9 custom Not specified
CNA Splunk Splunk Enterprise affected 10.0 10.0.12 custom Not specified
CNA Splunk Splunk Enterprise affected 9.4 9.4.17 custom Not specified

References

ReferenceSourceLinkTags
advisory.splunk.com/advisories/SVD-2026-1103 [email protected] advisory.splunk.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Pedro Cardoso (tvmpt) (en)

Additional Advisory Data

Solutions

CNA: Upgrade Splunk Enterprise versions 10.6.1, 10.4.5, 10.2.9, 10.0.12, and 9.4.17 or higher.

Workarounds

CNA: Turn off the HTTP PubSub broker by setting `disabled` = `true` in the `server.conf` configuration file if you do not use agent management over HTTP. For more information see [server.conf configuration specification file](https://help.splunk.com/en/data-management/splunk-enterprise-admin-manual/10.4/configuration-file-reference/10.4.4-configuration-file-reference/server.conf) in the Splunk documentation.

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.