Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Insufficient Session Expiration due to flawed session expiration logic
Summary
| CVE | CVE-2026-14950 |
|---|---|
| State | PUBLISHED |
| Assigner | CERTVDE |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-08-20 09:16:47 UTC |
| Updated | 2026-08-20 09:16:47 UTC |
| Description | An unauthenticated remote attacker in possession of a valid session identifier is able to continue using the session after it should have expired. This increases the risk associated with stolen, leaked, shared, or unattended sessions and may enable unauthorized continued access to the FDS web interface. |
Risk And Classification
Primary CVSS: v4.0 9.2 CRITICAL from [email protected]
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Problem Types: CWE-613 | CWE-613 CWE-613 Insufficient Session Expiration
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 9.2 | CRITICAL | CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 9.2 | CRITICAL | CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Primary | 9.8 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | CNA | CVSS | 9.8 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
CVSS v4.0 Breakdown
Attack Vector
NetworkAttack Complexity
LowAttack Requirements
PresentPrivileges Required
NoneUser Interaction
NoneConfidentiality
HighIntegrity
HighAvailability
HighSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Frauscher Sensortechnik | FDS 102 | affected 2.1.0 2.13.3 semver | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.certvde.com/en/advisories/VDE-2026-078 | [email protected] | www.certvde.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.