Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command
Summary
| CVE | CVE-2026-15570 |
|---|---|
| State | PUBLISHED |
| Assigner | Vestel |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-08-07 14:16:56 UTC |
| Updated | 2026-08-07 15:16:59 UTC |
| Description | An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0. |
Risk And Classification
Primary CVSS: v4.0 7.1 HIGH from 5431be70-064b-4f6a-be51-69eacabef109
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.002070000 probability, percentile 0.109210000 (date 2026-08-09)
Problem Types: CWE-918 | CWE-918 CWE-918 Server-Side request forgery (SSRF)
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | 5431be70-064b-4f6a-be51-69eacabef109 | Secondary | 7.1 | HIGH | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 7.1 | HIGH | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N |
CVSS v4.0 Breakdown
Attack Vector
AdjacentAttack Complexity
LowAttack Requirements
NonePrivileges Required
NoneUser Interaction
NoneConfidentiality
NoneIntegrity
HighAvailability
LowSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Vestel | Telefunken TE24553B45V2DZ Smart TV | affected V2.78.0.0 | Vestel MB181 / Voltron181 / TiVo OS |
| CNA | Vestel | Telefunken TE24553B45V2DZ Smart TV | unaffected V2.85.2.0 | Vestel MB181 / Voltron181 / TiVo OS |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| vestelinternational.com/security-advisories | 5431be70-064b-4f6a-be51-69eacabef109 | vestelinternational.com | |
| firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA... | 5431be70-064b-4f6a-be51-69eacabef109 | firebasestorage.googleapis.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Francesco Caligiuri (en)
Additional Advisory Data
Solutions
CNA: Upgrade the affected product to firmware version V2.85.2.0.
There are currently no legacy QID mappings associated with this CVE.