Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command

Summary

CVECVE-2026-15570
StatePUBLISHED
AssignerVestel
Source PriorityCVE Program / NVD first with legacy fallback
Published2026-08-07 14:16:56 UTC
Updated2026-08-07 15:16:59 UTC
DescriptionAn improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.

Risk And Classification

Primary CVSS: v4.0 7.1 HIGH from 5431be70-064b-4f6a-be51-69eacabef109

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS: 0.002070000 probability, percentile 0.109210000 (date 2026-08-09)

Problem Types: CWE-918 | CWE-918 CWE-918 Server-Side request forgery (SSRF)


VersionSourceTypeScoreSeverityVector
4.05431be70-064b-4f6a-be51-69eacabef109Secondary7.1HIGHCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/C...
4.0CNACVSS7.1HIGHCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N

CVSS v4.0 Breakdown

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Confidentiality
None
Integrity
High
Availability
Low
Sub Conf.
None
Sub Integrity
None
Sub Availability
None

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vendor Declared Affected Products

SourceVendorProductVersionPlatforms
CNA Vestel Telefunken TE24553B45V2DZ Smart TV affected V2.78.0.0 Vestel MB181 / Voltron181 / TiVo OS
CNA Vestel Telefunken TE24553B45V2DZ Smart TV unaffected V2.85.2.0 Vestel MB181 / Voltron181 / TiVo OS

References

ReferenceSourceLinkTags
vestelinternational.com/security-advisories 5431be70-064b-4f6a-be51-69eacabef109 vestelinternational.com
firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA... 5431be70-064b-4f6a-be51-69eacabef109 firebasestorage.googleapis.com
CVE Program record CVE.ORG www.cve.org canonical
NVD vulnerability detail NVD nvd.nist.gov canonical, analysis

Vendor Comments And Credit

Discovery Credit

CNA: Francesco Caligiuri (en)

Additional Advisory Data

Solutions

CNA: Upgrade the affected product to firmware version V2.85.2.0.

© CVE.report 2026

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.

CVE, CWE, and OVAL are registred trademarks of The MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. This site includes MITRE data granted under the following license.

Free CVE JSON API cve.report/api

CVE.report and Source URL Uptime Status status.cve.report