CVE-2026-25786
Summary
| CVE | CVE-2026-25786 |
|---|---|
| State | PUBLISHED |
| Assigner | siemens |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-05-12 10:16:44 UTC |
| Updated | 2026-05-12 14:19:41 UTC |
| Description | Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "communication" parameters page, the malicious code would be executed in the scope of their web session. |
Risk And Classification
Primary CVSS: v4.0 9.3 CRITICAL from [email protected]
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.000440000 probability, percentile 0.133910000 (date 2026-05-12)
Problem Types: CWE-79 | CWE-79 CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | [email protected] | Secondary | 9.3 | CRITICAL | CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/C... |
| 4.0 | CNA | DECLARED | 9.3 | CRITICAL | CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H |
| 3.1 | [email protected] | Primary | 9.1 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
| 3.1 | CNA | DECLARED | 9.1 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
CVSS v4.0 Breakdown
Attack Vector
NetworkAttack Complexity
LowAttack Requirements
NonePrivileges Required
HighUser Interaction
PassiveConfidentiality
HighIntegrity
HighAvailability
HighSub Conf.
HighSub Integrity
HighSub Availability
HighCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
HighUser Interaction
NoneScope
ChangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor Declared Affected Products
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| cert-portal.siemens.com/productcert/html/ssa-688146.html | [email protected] | cert-portal.siemens.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.