Plaintext Storage of Credentials in Configuration Backup in Nexxt Nebula 300+
Summary
| CVE | CVE-2026-31850 |
|---|---|
| State | PUBLISHED |
| Assigner | TuranSec |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-03-23 13:16:30 UTC |
| Updated | 2026-04-29 17:39:51 UTC |
| Description | Nexxt Solutions Nebula 300+ firmware through version 12.01.01.37 stores sensitive information, including administrative credentials and WiFi pre-shared keys, in plaintext within exported configuration backup files. These backup files can be obtained through legitimate functionality or other weaknesses and do not apply encryption or hashing, allowing attackers to directly extract sensitive information. |
Risk And Classification
Primary CVSS: v4.0 6.8 MEDIUM from 309f9ea4-e3e9-4c6c-b79d-e8eb01244f2c
CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS: 0.000280000 probability, percentile 0.079980000 (date 2026-05-02)
Problem Types: CWE-256 | CWE-256 CWE-256 Plaintext Storage of a Password
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 4.0 | 309f9ea4-e3e9-4c6c-b79d-e8eb01244f2c | Secondary | 6.8 | MEDIUM | CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/C... |
| 4.0 | CNA | CVSS | 6.8 | MEDIUM | CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
| 3.1 | [email protected] | Primary | 4.9 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N |
CVSS v4.0 Breakdown
Attack Vector
AdjacentAttack Complexity
LowAttack Requirements
NonePrivileges Required
HighUser Interaction
NoneConfidentiality
HighIntegrity
NoneAvailability
NoneSub Conf.
NoneSub Integrity
NoneSub Availability
NoneCVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
HighUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
NoneAvailability
NoneCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Hardware | Nexxtsolutions | Nebula300plus | - | All | All | All |
| Operating System | Nexxtsolutions | Nebula300plus Firmware | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Nexxt Solutions | Nebula 300 | affected <= 12.01.01.37 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| www.nexxtsolutions.com/connectivity/internal-products/ARN02304U6 | 309f9ea4-e3e9-4c6c-b79d-e8eb01244f2c | www.nexxtsolutions.com | Product |
| nexxt-connectivity-frontend.s3.amazonaws.com/media/docs/Nebula300+_v12.01.01.37.zip | 309f9ea4-e3e9-4c6c-b79d-e8eb01244f2c | nexxt-connectivity-frontend.s3.amazonaws.com | Product |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
Vendor Comments And Credit
Discovery Credit
CNA: Angel Barre (call4pwn) (en)
There are currently no legacy QID mappings associated with this CVE.