Electron: nodeIntegrationInWorker not correctly scoped in shared renderer processes
Summary
| CVE | CVE-2026-34775 |
|---|---|
| State | PUBLISHED |
| Assigner | GitHub_M |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-04-04 00:16:18 UTC |
| Updated | 2026-04-22 17:49:37 UTC |
| Description | Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 38.8.6, 39.8.4, 40.8.4, and 41.0.0, the nodeIntegrationInWorker webPreference was not correctly scoped in all configurations. In certain process-sharing scenarios, workers spawned in frames configured with nodeIntegrationInWorker: false could still receive Node.js integration. Apps are only affected if they enable nodeIntegrationInWorker. Apps that do not use nodeIntegrationInWorker are not affected. This issue has been patched in versions 38.8.6, 39.8.4, 40.8.4, and 41.0.0. |
Risk And Classification
Primary CVSS: v3.1 9.8 CRITICAL from [email protected]
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS: 0.000310000 probability, percentile 0.087730000 (date 2026-04-07)
Problem Types: CWE-653 | CWE-653 CWE-653: Improper Isolation or Compartmentalization
| Version | Source | Type | Score | Severity | Vector |
|---|---|---|---|---|---|
| 3.1 | [email protected] | Primary | 9.8 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 3.1 | [email protected] | Secondary | 6.8 | MEDIUM | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N |
| 3.1 | CNA | DECLARED | 6.8 | MEDIUM | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N |
CVSS v3.1 Breakdown
Attack Vector
NetworkAttack Complexity
LowPrivileges Required
NoneUser Interaction
NoneScope
UnchangedConfidentiality
HighIntegrity
HighAvailability
HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD Known Affected Configurations (CPE 2.3)
| Type | Vendor | Product | Version | Update | Edition | Language |
|---|---|---|---|---|---|---|
| Application | Electronjs | Electron | All | All | All | All |
Vendor Declared Affected Products
| Source | Vendor | Product | Version | Platforms |
|---|---|---|---|---|
| CNA | Electron | Electron | affected < 38.8.6 | Not specified |
| CNA | Electron | Electron | affected >= 39.0.0-alpha.1, < 39.8.4 | Not specified |
| CNA | Electron | Electron | affected >= 40.0.0-alpha.1, < 40.8.4 | Not specified |
| CNA | Electron | Electron | affected >= 41.0.0-alpha.1, < 41.0.0 | Not specified |
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| github.com/electron/electron/security/advisories/GHSA-xwr5-m59h-vwqr | [email protected] | github.com | Vendor Advisory |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.