CVE-2026-37220
Summary
| CVE | CVE-2026-37220 |
|---|---|
| State | PUBLISHED |
| Assigner | mitre |
| Source Priority | CVE Program / NVD first with legacy fallback |
| Published | 2026-06-01 15:16:34 UTC |
| Updated | 2026-06-01 15:16:34 UTC |
| Description | FlexRIC v2.0.0 crashes when an SCTP association is closed before an E2_SETUP_REQUEST is sent. The near-RT RIC assumes a mapping between SCTP association and E2 node always exists in the cleanup path and enforces this via assert(). A remote unauthenticated attacker can crash the near-RT RIC (port 36421) by simply completing an SCTP handshake and immediately disconnecting, without sending any E2AP message. |
Risk And Classification
Problem Types: n/a
Vendor Declared Affected Products
References
| Reference | Source | Link | Tags |
|---|---|---|---|
| gitlab.eurecom.fr/mosaic5g/flexric | [email protected] | gitlab.eurecom.fr | |
| github.com/MinamiKotor1/oran-security-advisories-zhongnan-luo/blob/main/... | [email protected] | github.com | |
| CVE Program record | CVE.ORG | www.cve.org | canonical |
| NVD vulnerability detail | NVD | nvd.nist.gov | canonical, analysis |
No vendor comments have been submitted for this CVE.
There are currently no legacy QID mappings associated with this CVE.